INSTALLATION AND
OPERATING INSTRUCTIONS
Melbourne: 03 8796 8600 Gold Coast: 07 5552 2600 Perth: 08 9350 2600
Sydney: 02 9853 2100 Townsville: 07 4750 3100 sales@astralpool.com.au
Brisbane: 07 3308 5400 Adelaide: 08 8152 7600 www.astralpool.com.au
Bolero ND
Cleaner
INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS
Astral Heat
Pumps

Questions and Answers

  • S
    Stephen ChristianJul 31, 2025
    How to troubleshoot an Astralpool BPM400A Heat Pump that will not start?
    • N
      Nicole ThomasAug 1, 2025
      If your Astralpool Heat Pump isn't starting, begin by ensuring the power to the heater is on and the pump is running. If the pump isn't running, start it. Check for any leaks or issues with the non-return valve if the pump is airlocked. Also, verify the filter is clean and the pump strainer basket isn't clogged. If the heater control is defective, shut off the electrical supply and call for service. Ensure the thermostat is on and set to the correct setpoint, adjusting the set temperature as needed based on the water temperature. If a fault condition is displayed due to the water being too hot, refer to the fault indication table.
  • T
    thomaswilliamsAug 15, 2025
    Why is my Astralpool BPM400A Heat Pump short cycling?
    • R
      Richard SotoAug 15, 2025
      Short cycling (rapid on and off operation) in your Astralpool Heat Pump can be due to several reasons. First, check for insufficient water flow by cleaning the filter and pump strainer. Second, defective wiring can cause this issue, so repair or replace the wiring if needed. Finally, a defective high limit or thermostat could be the culprit, requiring repair or replacement.

Summary

Installation Requirements and Safety

Electrical Safety & Phase Rotation

Mandates use of a multi-pole isolating switch and checks for correct phase rotation on 3-phase units.

Operational Guidelines and Warnings

Water Safety & Health Precautions

Advises on water temperature limits, health risks, and precautions for users.

Chemical Balance and Defrosting

Water Chemistry Maintenance

Emphasizes maintaining water balance to prevent corrosion and voiding warranty, listing recommended parameters.

Thermostat Controls and Settings

Setting Temperature & Clock Adjustment

Guides users on setting the temperature, reading outdoor temperature, and adjusting the real-time clock.

Controller Parameter Configuration

Temperature, Compressor & Defrost Settings

Details parameters related to temperature control, differences, limits, and compressor delay time.

Heat Pump Operating Principles

Temperature Control Modes Explained

Details the three temperature controlling modes: Refrigeration, Heat, and Auto, and their operating logic.

NA6888 Wiring Diagram

Controller Circuit Connections

Illustrates the internal and external wiring connections for the NA6888 thermostat controller.

Heat Pump Installation Procedures

Authorised Installation & Regulations

Stresses that installation must be done by authorized personnel following local and national rules.

Water Connections & Sanitiser Placement

Guides on the correct sequence of water connections and proper placement of sanitising devices to protect warranty.

Installation Clearances & Electrical

Airflow Clearance Requirements

Specifies the minimum clearances required around the heater for proper airflow and ventilation.

Electrical Connection Guidelines

Licensed Electrician & RCD Protection

Mandates that electrical connections must be made by a licensed electrician and protected by an RCD breaker.

Wiring Diagrams & Phase Rotation

Details the need for an isolating switch and checking phase rotation, with diagrams for single and three-phase connections.

Heat Pump Noise Management

Calculating Noise Impact Factors

Introduces a method to calculate noise impact using barrier, reflection, and distance factors.

Heat Pump Noise Distance Example

Step-by-Step Noise Calculation

Demonstrates a step-by-step calculation of the distance factor using example barrier and reflection values.

Determining Minimum Installation Distance

Guides on using a chart to find the minimum required installation distance from noise-sensitive areas based on calculated noise levels.

Further Heat Pump Installation Advice

Electrical Safety Checks & Phase Rotation

Emphasizes ensuring an electrical isolation switch is present and verifying compressor phase rotation for three-phase models.

Troubleshooting Common Issues

Heater Not Starting Troubleshooting

Lists common causes for the heater not starting and provides corresponding remedies for each issue.

Wiring Diagrams - BPM400;BPM600

Wiring Diagrams - BPM700;BPM800

Wiring Diagrams - BPT900

Astral Pool Warranty Details

Warranty Exclusions and Limitations