Questions and Answers

  • S
    silvajordanSep 1, 2025
    What does 'low ambient temperature protection' mean for my Astralpool PRO ELYO INVERBOOST NN?
    • A
      angela45Sep 1, 2025
      The 'low ambient temperature protection' message on your Astralpool Heat Pump indicates that the unit is either being used outside of its intended environment or that there is a sensor abnormality. Stop using the unit if it is beyond its operating scope, or change the sensor.
  • J
    Jamie RomanSep 12, 2025
    What to do if my Astralpool Heat Pump has a gas return sensor failure?
    • P
      peter09Sep 13, 2025
      If your Astralpool Heat Pump shows a gas return sensor failure, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • R
    rkimAug 30, 2025
    How to resolve communication failure between Main control board and Driving board in Astralpool PRO ELYO INVERBOOST NN Heat Pump?
    • C
      Crystal McclainAug 31, 2025
      A communication failure between the Main control board and Driving board in your Astralpool Heat Pump is likely caused by a poor connection of the communication wire or a damaged wire. Check the wire connection and replace the wire if necessary.
  • B
    Bonnie WallaceSep 15, 2025
    What should I do if my Astralpool PRO ELYO INVERBOOST NN shows an input power failure?
    • D
      Donald NormanSep 15, 2025
      If your Astralpool Heat Pump indicates an input power failure, it's likely due to supply voltage fluctuations. Check whether the voltage is stable.
  • A
    Alexander EsparzaSep 14, 2025
    What to do if my Astralpool Heat Pump has an exhaust piping sensor failure T6?
    • J
      Joel ThomasSep 14, 2025
      If your Astralpool Heat Pump shows an exhaust piping sensor failure T6, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • W
    William BrownSep 22, 2025
    What does compressor phase failure mean for my Astralpool PRO ELYO INVERBOOST NN Heat Pump?
    • T
      tonystoneSep 22, 2025
      Compressor phase failure in your Astralpool Heat Pump means that the compressors U, V, W are connected to one phase or two phases. Check the actual wiring according to the circuit diagram.
  • C
    Cassandra WardAug 27, 2025
    How to fix communication failure between controller and main board in Astralpool Heat Pump?
    • H
      Hannah WilliamsAug 27, 2025
      A communication failure between the controller and main board of your Astralpool Heat Pump is often due to a poor signal wire connection, a damaged signal wire, or a controller malfunction. Check and reconnect the signal wire, replace the signal wire, turn off the electricity supply and restart the machine, or replace the controller.
  • J
    Johnny RobersonAug 27, 2025
    What to do if my Astralpool PRO ELYO INVERBOOST NN Heat Pump displays a low pressure failure TS5?
    • J
      Joseph HarveyAug 27, 2025
      If your Astralpool Heat Pump is showing a low pressure failure TS5, it could be caused by a blocked EEV or jammed pipe system, abnormal motor speed or motor damage, or gas leakage. You should check the EEV and piping system, check the motor, use a high-pressure gauge to check the pressure value and check the refrigeration system.
  • M
    Michael SmithAug 26, 2025
    What causes T6 exhaust too high protection in Astralpool Heat Pump?
    • M
      martinmarkAug 27, 2025
      T6 exhaust too high protection in your Astralpool Heat Pump can result from a lack of gas, low water flow, a blocked piping system, or a faulty exhaust temperature sensor. Address this by checking the high-pressure gauge and filling with gas if needed, inspecting the waterway system and filtration pump, checking the piping system for blockages, and replacing the exhaust temperature sensor.
  • R
    Richard ThompsonAug 25, 2025
    Why is my Astralpool PRO ELYO INVERBOOST NN Heat Pump showing compressor current protection?
    • J
      Jason GrahamAug 26, 2025
      Compressor current protection in your Astralpool Heat Pump can occur due to several reasons: the compressor current being too large instantaneously, incorrect connection for compressor phase sequence, compressor accumulations of liquid and oil, a damaged compressor or driver board, abnormal water flow, or power fluctuations. To resolve this, check the compressor, compressor phase, power range, phase sequence connection, the waterway system and filtration pump, and mains power input.

Summary

3. Specifications

5. Location and connection

6. Electrical Wiring

6.1 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Models 71676/71677/71678/71679/71680).

6.2 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Model 71681).

6.3 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Models 71682/71683).

6.4 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Model 68822 (R410A)).

6.5 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Models 68821/68823 (R410A)).

6.6 Electrical connection

Guidelines and requirements for the electrical connection of the heat pump.

7. Start-up of the Heat Pump

7.3 Heating operation logic

Describes the logic and conditions for heating operation modes.

8. Troubleshooting

8.1 Error code display on LED wire controller

Lists error codes, their reasons, and solutions for LED wire controller displays.

8.2 Other Malfunctions and Solutions (No display on LED wire controller)

Troubleshooting guide for malfunctions not indicated by error codes on the controller.