EasyManua.ls Logo

Astralpool PRO ELYO INVERBOOST NN - User Manual

Astralpool PRO ELYO INVERBOOST NN
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SWIMMING POOL HEAT PUMP User and service manual
POMPE À CHALEUR POUR PISCINE Manuel d’installation et d’utilisation
ZWEMBAD WARMTEPOMP Gebruiker en service manual
BOMBA DE CALOR PARA PISCINA Manual del usuario y de servicio
SCHWIMMBAD - WÄRMEPUMPE Benutzer - und Wartungshandbuch
PISCINA POMPA DI CALORE Istruzioni per l'uso e di servizio
BOMBA DE CALOR DE PISCINA Manual do usuário e serviço
PRO ELYO INVERBOOST NN
EN
FR
NL
IT
ES
DE
PT

Questions and Answers

  • S
    silvajordanSep 1, 2025
    What does 'low ambient temperature protection' mean for my Astralpool PRO ELYO INVERBOOST NN?
    • A
      angela45Sep 1, 2025
      The 'low ambient temperature protection' message on your Astralpool Heat Pump indicates that the unit is either being used outside of its intended environment or that there is a sensor abnormality. Stop using the unit if it is beyond its operating scope, or change the sensor.
  • A
    Andrew ThomasSep 2, 2025
    What causes piping temperature too high protection under cooling mode T3 in Astralpool PRO ELYO INVERBOOST NN Heat Pump?
    • C
      Charles AlexanderSep 2, 2025
      Piping temperature too high protection under cooling mode T3 in your Astralpool Heat Pump can be caused by a high ambient or water temperature, or an abnormal refrigeration system. Check the scope of using and the refrigeration system.
  • M
    Mary JohnsonSep 3, 2025
    What to do if my Astralpool PRO ELYO INVERBOOST NN Heat Pump displays IPM module protection?
    • G
      Gary RuizSep 3, 2025
      If your Astralpool Heat Pump displays an IPM module protection error, it could be due to a data mistake, wrong compressor phase connection, compressor liquid and oil accumulation, or a damaged compressor or driver board. You can try turning off the electricity supply and restarting after 3 minutes, changing the driver board, or checking the compressor sequence connection.
  • S
    Susan EricksonSep 4, 2025
    What does 'VDC voltage too low protection' mean for my Astralpool Heat Pump?
    • A
      Alexis WrightSep 4, 2025
      The 'VDC voltage too low protection' error in your Astralpool Heat Pump indicates that the line voltage is too low or the driver board is damaged. Check if the power is in the normal range or change the driver board.
  • A
    anthony61Sep 4, 2025
    What causes input current over high protection in my Astralpool PRO ELYO INVERBOOST NN?
    • J
      Jennifer JohnsonSep 4, 2025
      Input current over high protection in your Astralpool Heat Pump can be caused by a large momentary compressor current, abnormal water flow, power fluctuations, or an incorrect PFC inductor. Try checking the compressor, the waterway system, the power range, and if the correct PFC inductor is used.
  • D
    Deanna ContrerasSep 5, 2025
    How to troubleshoot IPM module thermal circuit abnormality in Astralpool Heat Pump?
    • W
      william59Sep 5, 2025
      An abnormal IPM module thermal circuit in your Astralpool Heat Pump can be caused by an output abnormality of the IPM module thermal circuit or a problem with the fan motor (abnormal or damaged) or a broken fan blade. Try changing the driver board, checking if the motor speed is too low or fan motor is damaged, or changing the fan blade.
  • M
    Mrs. Cassie Anderson MDSep 6, 2025
    What to do if my Astralpool Heat Pump shows IPM module temperature too high protection?
    • S
      Scott JohnsonSep 6, 2025
      If your Astralpool Heat Pump displays an IPM module temperature too high protection error, it could be due to an output exception of the IPM module thermal circuit, an abnormal or damaged motor, or a broken fan blade. Try changing the driver board, checking if the fan motor speed is too low or fan motor is damaged, or changing the fan blade.

Summary

3. Specifications

5. Location and connection

6. Electrical Wiring

6.1 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Models 71676/71677/71678/71679/71680).

6.2 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Model 71681).

6.3 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Models 71682/71683).

6.4 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Model 68822 (R410A)).

6.5 Inverter swimming pool heat pump wiring diagram

Wiring diagram for inverter pool heat pumps (Models 68821/68823 (R410A)).

6.6 Electrical connection

Guidelines and requirements for the electrical connection of the heat pump.

7. Start-up of the Heat Pump

7.3 Heating operation logic

Describes the logic and conditions for heating operation modes.

8. Troubleshooting

8.1 Error code display on LED wire controller

Lists error codes, their reasons, and solutions for LED wire controller displays.

8.2 Other Malfunctions and Solutions (No display on LED wire controller)

Troubleshooting guide for malfunctions not indicated by error codes on the controller.

Astralpool PRO ELYO INVERBOOST NN Specifications

General IconGeneral
CategoryHeat Pump
Max Water Temperature40°C
RefrigerantR32
IP RatingIPX4
Ambient Temperature Range43°C