3
InstallationandGeneralMaintenanceManualVironP300PoolPump
WARNINGSDURINGINSTALLATIONANDASSEMBLYWORK
Ͳ Whenconnectingtheelectricalwiringtothemachinemotor,checkthelayoutinsidethe
connectionboxandmakesuretherearenopiecesofwiringinsideafterithasbeen
closedandthattheearthingconductoriscorrectlyconnected.Connectthemotorinline
withthewiringdiagramattachedtothemachine.
Ͳ Makesurethattheelectricalwiringconnectionstothemachineterminalboxarewell
mountedandscrewedtighttotheconnectionterminals.
Ͳ Theelectricalinstallationofthepumpmustincludedifferentialprotectionofavalueno
greaterthan30mA.
Ͳ Correctly
usethesealoftheterminalboxfortheelectricalmotortopreventwater
gettingin.Likewise,positionandtightentheglandinsidethecableductoftheterminal
box.
Ͳ Makesurethatwaterisunabletoenterthemotorortheliveelectricalparts.
Ͳ Wheretheintendeduseisnotasindicated,additionaltechnicaladaptationsand
regulationsmayberequired.
WARNINGSDURINGSTARTͲUP
Beforestartingthemachine,checkthecalibrationoftheelectricalprotectiondevicesonthe
motorandthattheprotectionagainstelectricalandmechanicalcontactsiscorrectly
positionedandsecure.
NOTE

Thepoolshouldnotbeusedwhilethepumpingequipmentisrunning. 
Donotusethepumpifanyoneisincontactwiththewater.
WARNINGSDURINGASSEMBLYANDMAINTENANCEWORK
Ͳ Takeintoaccountnationalinstallationregulationswhenassemblingandinstallingthe
pumps.
Ͳ Makesurethatwaterisunabletoenterthemotorortheliveelectricalparts.
Ͳ Avoidcontactatalltimesevenaccidentallywithmovingmachinepartswhilethe
machineisrunningand/orbeforeitcomestoacompletestandstill.
Ͳ Waitforthemachinetocometoahaltbeforehandlingit.
Ͳ Beforeanyelectricalormechanicalmaintenanceoperation,disconnecttheunitfrom
thepowersupplyandblockthestartͲupdevices.
Ͳ Followthestepsbeforehandlingthemachine:
1. Disconnectthemachinefromthemains.
2. BlockallstartͲupdevices.
3. Checkthatthereisnovoltageincircuits,evenintheauxiliarycircuitsandadditional
services.
4. Waitfortheimpellortocometoacompletestandstill.
Thelistindicatedmustbeusedasaguidelineandisnotbindingforsafetypurposes.There
maybeparticularsafetyregulationsinspecificstandards.
Ͳ Forregularcontrol:
x Checkthatthemechanicalpartsaretightlysecuredandchecktheconditionofthe
screwssupportingthemachine.
x Checkthatthepowerconductorsandisolatingpartsareintheircorrectposition,and
secureandingoodstateofrepair.