Timing
Maintenance Check
Service action (if required)
Fortnightly
Check cell for calcium build up
Check water chemistry
Check cable connections to cell
Soak cell in mixture of 10 parts water to 1
part acid. Use a soft brush only if required
Balance pH in pool and adjust output of unit
to ensure satisfactory production of
chlorine.
Adjust pins by separating if not held firmly in
place. Ensure no water contact is occurring
with pins
Three Monthly
Check cell connections for leaks
Isolate Pump, turn power off, clean and
grease O rings or replace if necessary
Spray a surface insecticide on the surfaces
around the unit to prevent ant and insect
ingress.
Six Monthly
Check chlorine levels and pump operating
hours
Prevent insect ingress to controller
Adjust timer and output depending on
demand for current season.
Turn controller off, use an insect spray and
spray onto walls around controller. Do not
spay directly into unit.
Important note: Regular maintenance is important to ensure long life and trouble free performance of your pool
equipment. If unable to perform the maintenance yourself, contact your local AstralPool office who will arrange a trained
service technician to perform the maintenance for you.
Record your Equipment details here for quick reference:
Model No.: ____________________________
Serial No.: ____________________________