Installation and Operation Instructions
Astria™ Aries Direct-Vent Gas Fireplaces
P/N 900004-01 Rev. G 03/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-03.
PFS
®
USC
Models
Aries 33xxx * Aries 35xxx * Aries 40xxx * Aries 45xxx *
P900004-01
* “xxx” indicates unique model identifiers.
This manual covers all Astria™ Aries models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Report No. F13-094

Questions and Answers

  • D
    Derrick AllenAug 15, 2025
    What to do if nothing happens when Astria Indoor Fireplace is turned ON/OFF?
    • A
      Alicia ClarkAug 15, 2025
      If nothing happens when you turn your Astria Indoor Fireplace ON/OFF, there are several things you can check: * Ensure the wall switch plate is set to REMOTE. * Verify the gas supply and gas shutoff valves are open, allowing gas to reach the fireplace. * Check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • C
    Crystal WilliamsAug 18, 2025
    Why won't my Astria Indoor Fireplace main burner light but the igniter is sparking?
    • S
      samuel81Aug 19, 2025
      If the main burner of your Astria Indoor Fireplace doesn't light even though the igniter is sparking, the issue could be due to several reasons: * Check that the gas supply and shutoff valves are open, ensuring gas is reaching the fireplace. * Inspect the control compartment for any loose wiring to the valve or ignition module. If you find loose wires, you may need to call a service technician. * Purge the gas line of air. If you're not comfortable doing this, call a service technician. * Replace the unit battery backup.
  • M
    Madison Flores DDSAug 22, 2025
    How to fix Astria Indoor Fireplace when pilot won't stay lit?
    • L
      Lisa RodriguezAug 22, 2025
      If the pilot light on your Astria Indoor Fireplace won't stay lit after following the lighting instructions, it might be due to a defective pilot generator (thermocouple). Ensure the pilot flame is directly impinging on the thermocouple. Try cleaning and/or adjusting the pilot for maximum flame impingement. Also, make sure the connection between the valve and thermocouple is tight and secure.
  • J
    Jessica MoranAug 25, 2025
    What to do if my Astria Aries 33 Indoor Fireplace burner comes on but then goes out?
    • K
      Krista BranchAug 26, 2025
      If the main burner of your Astria Indoor Fireplace comes on but then goes out, consider the following: * Check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. * Inspect the control compartment for any loose wires to the valve or ignition module. If necessary, call a service technician. For the following potential issues, it is recommended to contact a service technician: * If the pilot flame is not engulfing the sensor. * If there's an obstructed vent system.
  • M
    Melinda MaddoxAug 28, 2025
    How to troubleshoot frequent pilot/burner outage problem in Astria Aries 33 Indoor Fireplace?
    • C
      Cynthia YuAug 28, 2025
      If you're experiencing frequent pilot/burner outages with your Astria Indoor Fireplace, the pilot flame may be too low or blowing too high, causing the pilot/valve safety to drop out. Try cleaning and/or adjusting the pilot flame to ensure maximum flame impingement on the thermocouple.
  • D
    Daniel LeeSep 1, 2025
    What causes soot on the logs and glass of Astria Aries 33 and how to fix it?
    • J
      John HicksSep 1, 2025
      Soot on the logs and glass of your Astria Indoor Fireplace can be caused by several factors: * Excessive flame impingement on the logs: Properly position the logs. * Initial fireplace operation: A white film may develop during the first few fires. Clean the glass after each use after it has completely cooled. * Improper vent restrictor setting: Open the air shutter by adjusting the air shutter adjustment lever. * Improper air shutter opening: Open the air shutter by pushing in the rod.
  • W
    wmorrisSep 4, 2025
    How to fix poor or blue flame in Astria Aries 33?
    • C
      Carol AnthonySep 4, 2025
      A poor or blue flame in your Astria Indoor Fireplace can be caused by a door seal that is not properly aligned, leading to gaps and air leaks. To resolve this, remove and realign the door to ensure the gasket seal is fully engaged around the door frame.
  • A
    Ashley JoyceSep 7, 2025
    What causes spark igniter to not light pilot in Astria Aries 33?
    • S
      smithjenniferSep 7, 2025
      If the spark igniter on your Astria Indoor Fireplace won't light the pilot after repeated attempts, here are a few potential causes: * Defective igniter: Check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the igniter. * Defective or misaligned electrode: Light the pilot with a match. If it lights, turn off the pilot and try the igniter again. If it lights, a longer purge period is recommended. If it doesn't light, check the gap at the electrode and pilot (should be 1/8"). If the gap is correct, replace the pilot. * Gas supply pressure errant: Check the inlet gas pressure to ensure it's within the limits on the rating plate. * Pilot orifice plugged: Clean or replace the pilot orifice.