Installation and Operation Instructions
Astria™ Aries Direct-Vent Gas Fireplaces
P/N 900004-01 Rev. G 03/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-03.
PFS
®
USC
Models
Aries 33xxx * Aries 35xxx * Aries 40xxx * Aries 45xxx *
P900004-01
* “xxx” indicates unique model identifiers.
This manual covers all Astria™ Aries models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Report No. F13-094

Questions and Answers

  • L
    Laurie JonesAug 15, 2025
    What to do if nothing happens when Astria Indoor Fireplace is turned ON/OFF?
    • E
      elizabeth16Aug 15, 2025
      If nothing happens when you turn your Astria Indoor Fireplace ON/OFF, there are several things you can check: * Ensure the wall switch plate is set to REMOTE. * Verify the gas supply and gas shutoff valves are open, allowing gas to reach the fireplace. * Check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • R
    Renee SmithAug 18, 2025
    Why won't my Astria Aries 35 main burner light but the igniter is sparking?
    • A
      Ashley AllenAug 18, 2025
      If the main burner of your Astria Indoor Fireplace doesn't light even though the igniter is sparking, the issue could be due to several reasons: * Check that the gas supply and shutoff valves are open, ensuring gas is reaching the fireplace. * Inspect the control compartment for any loose wiring to the valve or ignition module. If you find loose wires, you may need to call a service technician. * Purge the gas line of air. If you're not comfortable doing this, call a service technician. * Replace the unit battery backup.
  • L
    Lisa KimAug 21, 2025
    How to fix Astria Aries 35 when pilot won't stay lit?
    • A
      Anthony PachecoAug 21, 2025
      If the pilot light on your Astria Indoor Fireplace won't stay lit after following the lighting instructions, it might be due to a defective pilot generator (thermocouple). Ensure the pilot flame is directly impinging on the thermocouple. Try cleaning and/or adjusting the pilot for maximum flame impingement. Also, make sure the connection between the valve and thermocouple is tight and secure.
  • R
    Robert WatkinsAug 26, 2025
    What to do if my Astria Aries 35 Indoor Fireplace burner comes on but then goes out?
    • S
      Susan HernandezAug 26, 2025
      If the main burner of your Astria Indoor Fireplace comes on but then goes out, consider the following: * Check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. * Inspect the control compartment for any loose wires to the valve or ignition module. If necessary, call a service technician. For the following potential issues, it is recommended to contact a service technician: * If the pilot flame is not engulfing the sensor. * If there's an obstructed vent system.
  • M
    Micheal HolmesAug 28, 2025
    How to troubleshoot frequent pilot/burner outage problem in Astria Indoor Fireplace?
    • M
      Megan SmithAug 29, 2025
      If you're experiencing frequent pilot/burner outages with your Astria Indoor Fireplace, the pilot flame may be too low or blowing too high, causing the pilot/valve safety to drop out. Try cleaning and/or adjusting the pilot flame to ensure maximum flame impingement on the thermocouple.
  • S
    Shane NolanAug 31, 2025
    What causes soot on the logs and glass of Astria Aries 35 and how to fix it?
    • R
      Ralph GilesAug 31, 2025
      Soot on the logs and glass of your Astria Indoor Fireplace can be caused by several factors: * Excessive flame impingement on the logs: Properly position the logs. * Initial fireplace operation: A white film may develop during the first few fires. Clean the glass after each use after it has completely cooled. * Improper vent restrictor setting: Open the air shutter by adjusting the air shutter adjustment lever. * Improper air shutter opening: Open the air shutter by pushing in the rod.
  • P
    pbakerSep 4, 2025
    How to fix poor or blue flame in Astria Aries 35?
    • H
      Heather LawsonSep 4, 2025
      A poor or blue flame in your Astria Indoor Fireplace can be caused by a door seal that is not properly aligned, leading to gaps and air leaks. To resolve this, remove and realign the door to ensure the gasket seal is fully engaged around the door frame.
  • W
    Walter CardenasSep 7, 2025
    What causes spark igniter to not light pilot in Astria Aries 35 Indoor Fireplace?
    • A
      Angelica VelazquezSep 7, 2025
      If the spark igniter on your Astria Indoor Fireplace won't light the pilot after repeated attempts, here are a few potential causes: * Defective igniter: Check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the igniter. * Defective or misaligned electrode: Light the pilot with a match. If it lights, turn off the pilot and try the igniter again. If it lights, a longer purge period is recommended. If it doesn't light, check the gap at the electrode and pilot (should be 1/8"). If the gap is correct, replace the pilot. * Gas supply pressure errant: Check the inlet gas pressure to ensure it's within the limits on the rating plate. * Pilot orifice plugged: Clean or replace the pilot orifice.

Summary

General Information

Important Safety Information

Essential safety guidelines and warnings for product use, covering hazards and precautions.

Fireplace Installation, Operation, and Maintenance Notices

Key notices for proper installation, operation, and maintenance procedures.

Packaging

Details about the product's packaging contents and included components.

Introduction

Overview of the direct-vent gas fireplace heaters and their features.

Approved Vent Components

Information on the specific vent components approved for use with these fireplaces.

Codes and Standards

Compliance with national and local safety standards and codes.

BTU Input

Technical specifications for the fireplace's heating output (BTU/HR).

Gas Pressure

Information on gas pressure requirements for proper operation.

Orifice Sizes

Details on burner orifice sizes for sea level to high altitude installations.

Deration

How altitude affects BTU output and necessary adjustments.

Installation

Requirements for the Commonwealth of Massachusetts

Specific installation rules and regulations for Massachusetts.

Cold Climate Insulation

Guidance on insulating the fireplace for cold climate installations.

Manufactured Home Requirements

Specific installation guidelines for manufactured homes.

Location

Factors to consider when choosing a location for the fireplace.

Vent Termination Clearances

Critical clearance requirements for vent termination.

Minimum Clearances to Combustibles

Safety clearances required around combustible materials.

Wall Finishes; Surrounds; Mantels

Guidelines for installing finishes around the fireplace.

Installation Preparation

Steps to prepare for fireplace installation.

Installation Sequence

A step-by-step guide to the fireplace installation process.

Route the Gas Supply Line to the Fireplace

Instructions for routing and connecting the gas supply line.

Install the Vent System

Detailed instructions for installing the direct-vent system.

Complete the Field Wiring

Guidance on completing electrical wiring for the fireplace.

Connect the Gas Line

Steps for connecting the gas line to the appliance.

Verify Proper Fireplace Operation

Procedures to check fireplace functionality after installation.

Adjust the Air Shutter to Ensure Proper Flame Appearance

How to adjust the air shutter for optimal flame appearance.

Attach the Safety-in-Operation Warning Labels

Crucial steps for affixing safety labels for user awareness.

Operation

Burn-in Period

Information on the initial operation and break-in period, including odor management.

Accessing the Control Compartment

How to access and open the fireplace's control compartment.

Installing the Firebox Liners

Steps for installing interior firebox liners for traditional models.

Installing the Glass Media

Instructions for installing decorative glass media for contemporary models.

Installing the Logs, Volcanic Stone, and Glowing Embers

How to properly install logs, stone, and embers for optimal flame.

Installing the Aries 33 and 35 logs

Specific log placement instructions for Aries 33/35 models.

Installing the Aries 40 and Aries 45 logs

Specific log placement instructions for Aries 40/45 models.

Installing and removing the glass door

Procedures for installing and removing the glass door assembly.

Maintenance

Inspecting the glass gasket

How to visually inspect the gasket on the backside of the glass door.

Cleaning the control compartment

Instructions for maintaining cleanliness of the control compartment.

Removing and cleaning the logs

Steps for carefully removing and cleaning fireplace logs.

Removing and cleaning the glass media

Procedures for removing and cleaning decorative glass media.

Inspecting the wiring

Checking electrical connections for safety and proper function.

Accessory Components

Touch-Up Paint Kits

Kits for repairing minor scratches and discoloration of the fireplace finish.

Forced Air Kits

Information on optional blower kits for forced air circulation.

Glowing Embers and Volcanic Stone

Components for decorative elements: glowing embers and volcanic stone.

Glass Media

Decorative glass media options for contemporary fireplace models.

Brickaded Firebox Liner Kits

Replacement firebox liner kits available in different finishes.

Termination Guard Kits

Kits for termination guards to minimize exposure to hot surfaces.

Thermostatic Control Kits

Control kits offering thermostatic and manual operation modes.

ON;OFF and Timer Control Kits

Control kits featuring timed ON/OFF operation and manual control.

Unit-Mountable Rocker Switch Kit

Rocker switch kit for ON/OFF operation within the control compartment.

OFF;ON Wall Switch Kit

Wall switch kit to control fireplace burner or blower operation.

Variable Speed Wall Switch Kit

Wall switch kit for variable speed control of optional blowers.

Lighting Instructions

Millivolt Gas Valve

Step-by-step instructions for lighting the pilot and burner for millivolt systems.

Electronic Gas Valve

Operating instructions for lighting the pilot and burner for electronic systems.

Troubleshooting

Troubleshooting Millivolt Systems

Common issues and solutions for millivolt ignition systems.

Troubleshooting Electronic Systems

Common issues and solutions for electronic ignition systems.

Replacement Parts

Warranty

Astria Aries 35 Specifications

General IconGeneral
BTU Input (NG)35, 000 BTU
BTU Input (LP)35, 000 BTU
VentingDirect Vent
Fuel TypeNatural Gas (NG) or Liquid Propane (LP)
Ignition TypeElectronic