Temperature
Range Resolution Accuracy
-40~1370°C 1°C -40°C~150°C:±(1% + 4)
-40°F~302°F
1°F
±(5% + 4)
302°F~2000°F ±(2.5% + 3)
Overload Protection: F0.4A/600V Fuse
DC Current
Range Resolution Accuracy
600µA 0.1µA
±(0.8% of rdg + 5dgts)
6000µA 1µA
60mA 10µA
600mA 100µA
6A 1mA
±(1.5% of rdg + 3dgts)
10A 10mA
Overload Protection:
“mA” Jack: F0.4A/600V fuse
“10A” Jack: F10A/600V fuse
Max.Input Current:
“mA” jack: 600mA
“10A” jack: 10A
(For measurements >5A: Duration <10 seconds, interval >15 minutes)
Voltage Drop:
600µA, 60mA: 60mV
6000µA, 600mA and 10A ranges: 600mV
Transistor hFE Test (Connect Adapter )