7. Saving
Only one of the 26 vibration sets can be active at a time. Before switching the vibration set ID
in the ‘Platform’ tab or the ‘Hopper’/‘Outputs’ tab, the user has to save the modifications
made in the “flash memory”, i.e. in the Asycube memory, or discard them (see Figure 7-1).
Also, note that flashing the parameters from the ‘Platform’ tab automatically flashes all the
parameters of the selected vibration set (i.e. including the parameters in the
‘Hopper’/‘Outputs’ tab) and likewise when flashing from the ‘Hopper’/‘Outputs’ tab.
Figure 7-1: Vibration set ID
Switching between sequences does not require flashing the parameters beforehand, you may
freely jump from a sequence to another and modify parameters. Also, note that a copy/paste
function is available not only to copy a whole sequence but also in the context of vibration
tuning.
Figure 7-2: Sequence ID and copy/paste function
Flashing the parameters, whether parameters of the vibration sets or the sequences, saves
them in the Asycube which means that they do not need loading from an external file.
Nevertheless, you can import/export .xml files via the HMI (see Table 7-1).
Figure 7-3: Import/export an .xml file