Installation & Servicing Instructions ATAG E-Series
8
5.1 Dimensions
type of unit E22S E22C E32S E32C
A height
mm 650 650 650 650
B height with expansion vessel
mm - - 870 870
C width
mm 500 500 500 500
Ddepth
mm 395 395 395 395
E left side / flue gas exhaust
mm 335 335 335 335
F centre to centre / flue - airintake
mm 120 120 120 120
G back / flue gas exhaust
mm 270 270 270 270
H left side / gas pipe
mm 250 250 250 250
J left side / flow pipe
mm 150 150 150 150
K left side / return pipe
mm 350 350 350 350
L left side / condensation pipe
mm 405 405 405 405
N left side / cold water pipe
mm 285 285
P left side / hot water pipe
mm 215 215
Q pipe lenght of g*
mm 19 19 215 215
R pipe lenght of c*
mm 40 40 40 40
S pipe lenght of c and f;r;k and w*
mm 50 50 160 160
T back / centre of pipe c;k and w*
mm 26 26 26 26
U back / centre of pipe f;g and r*
mm 50 50 50 50
dimensions table 1
dimensions (in mm) figure 1
wall
ceiling
minimal 250mm
minimal
10 mm
D
F
R
S
C
P
T
Q
H
J
K
L
G
U
N
E
B
A
type of unit E22S E22C E32S E32C
air supply / flue gas system
mm 60 / 100 60 / 100 60 / 100 60 / 100
gas pipe - g
½"
female
½"
female
½"
female
½"
female
central heating flow pipe - f
22 mm 22 mm ¾" ext. ¾" ext.
central heating return pipe - r
22 mm 22 mm ¾" ext. ¾" ext.
condensation discharge pipe - c
22 mm 22 mm 22 mm 22 mm
cold water pipe - k
15 mm ½"ext.
hot water pipe - w
15 mm ½"ext.
connection diameters table 2