Checking combustion CO
2
The CO
2
percentage is set in the factory. This has to be checked during commissioning,
inspection, maintenance and in case of a failure.
CO
2
High Load reading
CO
2
Low Load reading
Finally, the CO
2
percentage at low load must
be checked:
Press on the DHW - button until the minimum
value (0%) has been reached (low load)
This can be verified by means of the following action:
Set the external controls to call for heat
Make sure the boiler is operational and can get rid of the heat it produces
Calibrate the flue gas analyser
Place the lance of the flue gas analyser into the flue gas test point
Press both + buttons for 6 seconds
When the flame symbol and supply water temperature appears in the display the boiler
will be in max heat output CH.
Press 1x the eco - button; the display shows:
1. Flow temp
2. Fan speed
Press both + buttons again for 6 seconds;
The boiler will switch to max heat output DHW for iC range or again max heat output
CH for iS & iR range.
Press 1x the eco - button; the display shows:
1. Flow temp
2. XX% (heat capacity)
3. Fan speed
Then with the + / - button for DHW you can go to a dierent load, anything between full (100%)
and low load (0%)
°C
NOTE: UNDER ALL CIRCUMSTANCES THE CO
2
AT LOW LOAD MUST BE LOWER THAN THE CO
2
AT FULL LOAD.
End of measuring:
Press the ESC button ( button).
The device switches o. The display shows
for 2 seconds code 180 or 181.
This complete the procedure.
FULL LOAD NATURAL GAS G20 PROPANE GAS G31
CO
2
Nominal 9.0% Nominal 10.3%
Minimum 8.6% – Maximum 9.6% Minimum 9.9% – Maximum 11.0%
If required, you
may turn the
setting screw to
set the correct CO
2
percentage.
NATURAL GAS G20 LPG G31
Full load recorded Accepted low load range Full load recorded Accepted low load range
9.6% 9.3% – 7.5% 11.0% 10.9% – 8.9%
9.5% 9.2% – 7.5% 10.9% 10.8% – 8.9%
9.4% 9.1% – 7.5% 10.8% 10.7% – 8.9%
9.3% 9.0% – 7.5% 10.7% 10.6% – 8.9%
9.2% 8.9% – 7.5% 10.6% 10.5% – 8.9%
9.1% 8.8% – 7.5% 10.5% 10.4% – 8.9%
9.0% 8.7% – 7.5% 10.4% 10.3% – 8.9%
8.9% 8.6% – 7.5% 10.3% 10.2% – 8.9%
8.8% 8.5% – 7.5% 10.2% 10.1% – 8.9%
8.7% 8.4% – 7.5% 10.1% 10.0% – 8.9%
8.6% 8.3% – 7.5% 10.0% 9.9% – 8.9%
9.9% 9.8% – 8.9%