18
Please note!
Terminal boxes fastened as per Fig. 6 are to be turned
counter-clockwise by a maximum of one turn away from the
thread end stop. Screwed-on covers must be duly secured.
Anti-corrosion protection can be achieved with non-hardening sealing
materials or sealing grease in particular on the processed sealing surfaces of
the covers of terminal boxes having the following degree of protection:
"pressure-resistant encapsulation, EEx d IIC(B) marking".
The approved sealing materials are:
• For threads and surfaces:
Hylomar, by Marston-Domsel or
• for surfaces:
Admosit and Fluid-D, by Teroson.
Please note!
In the case of "increased safety" terminal boxes the gaskets
used are included in the approval. Only original gaskets are
to be used.
Please note!
"Pressure-resistant encapsulation“ terminal boxes must be
sealed by means of approved cable or line lead-ins.