Frequency | 50Hz |
---|---|
Type | Infrared |
Mounting | Wall-mounted |
Wattage | 1500W |
Power | 1500W |
Safety Features | Overheat protection |
Button 1: Change mode, confirm, or access program setting.
Button 2: Decrease temp/time or select Economy mode.
Button 3: Increase temp/time or select Comfort mode.
Button 4: Power on/off, Frost Protection, Engineering menu.
Full time Comfort mode display shows two bar rows and a sun icon.
Full time Economy mode shows one bar row and a moon icon.
Frost protection mode is factory set at 7°C, shown by a snowflake.
Program mode shows day numbers and current day/time indicators.
Central Control mode is not used and shows a copyright symbol.
Turn on heater with Power button (4) and set time/day.
Use '+' and '-' buttons to set Comfort temperature.
Hold '+' and '-' buttons together for 5 seconds to lock/unlock.
Diagram shows days, temp, modes, flame indicator, and clock.
Press Mode button until 'PROG' shows, use buttons to set daily schedule.
Example of setting Economy, Comfort, and Frost Protection modes.
Set day and time after programming, or on first use.
Part 1 sets the °C difference for Economy mode vs Comfort mode.
Part 2 sets radiator's temperature offset from observed room temp.
Part 4 sets the number of seconds the backlight remains lit.