VT36 TPMS TOOL user guide
UM-36400C-U User manual ATEQ VT36 Page 20/32
1.1. CHANGE ZONE SETTINGS
SETTINGS
> ZONE : EUROPE
UNITS : PSI/°F
FORMAT : AUTO
BUZZER ON : YES
Up or down to select the zone.
Press to enter.
ZONE
> AMERICA
EUROPE
KOREA
DATABASE
PLEASE WAIT...
A first starting or after a factory reset, the zone option appears on the screen.
For apply a factory reset to the device, please use the WebVT software.
Connect the VT36 device to the PC, when recognized, enter into the "Settings" menu and
then click on the "Factory reset" button.
1.2. CHANGE UNITS SETTINGS
SETTINGS
ZONE : EUROPE
> UNITS : PSI/°F
FORMAT : AUTO
BUZZER ON : YES
Scroll up and down to select function
or settings.
Enter settings parameter.
Complete listing.
> PSI/°F
PSI/°C
kPa/°C
kPa/°F
bar/°F
bar/°C
Up or down to select the desired
change.
Press to confirm the change
and return to settings.
Press to return settings
without change.