EasyManua.ls Logo

Atex ECO 6 - User Manual

Default Icon
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ECO 6 – User and installation manual
Release 5.1 1
Question and Answer IconNeed help?

Do you have a question about the Atex ECO 6 and is the answer not in the manual?

Summary

Safety Information

General Safety Information

Provides essential safety information for the controller and its installation.

Display Panel Options

Display Panel Options

Details various display panel options available for the ECO 6 controller.

Technical Features

ECO 6 Controller Specifications

Details the core technical specifications of the ECO 6 controller unit.

Board Layout and Settings

Controller Board Layout

Illustrates the physical layout and component placement on the ECO 6 controller board.

Board Address Settings

Configuration settings for board address selection.

CANBUS Termination Resistor

Details the CANBUS termination resistor settings.

Monitoring LEDs and Drill Map

Monitoring LED Explanations

Explains the function and meaning of the various monitoring LEDs.

Outputs LED Status

Describes the LEDs indicating the status of relay outputs.

Probe Status Check

Information on checking the status of connected probes.

Power Supply LED Status

Details the LEDs indicating power supply status.

Communication LED Status

Explains LEDs related to communication status.

Installation Drill Map

Provides a dimensional drawing for drilling installation purposes.

Installation Procedures

Installation Guide

Guides on the proper installation procedures for the controller and display.

Display Panel Installation

Instructions for installing the display panel.

Controller Board Installation

Details on installing and connecting the ECO 6 controller board.

I;O Flying Connector Guide

Information on I/O flying connectors for digital inputs and probes.

ATEX Testing System Compatibility

Compatibility information with ATEX testing systems.

Analog and Digital Inputs

Analog and Digital Input Setup

Explains the setup and connection of analog and digital inputs.

Thermostat Probe (S1) Installation

Instructions for installing and configuring the thermostat probe (S1).

Evaporator Probe (S2) Installation

Guidance on positioning and connecting the evaporator probe (S2).

Condenser Probe (S3) Installation

Instructions for installing and connecting the condenser probe (S3).

Door Switch Input (D1)

Details on connecting the door switch to digital input D1.

High Pressure Switch Input (D2)

Information on connecting the high pressure switch to digital input D2.

Relay Output Configuration

Relay Output Configuration

Describes the configuration of relay outputs for various actions.

Cooling Operation

Cooling Operation Mode

Details the cooling operation mode and related parameters.

Thermostatic Control

Explains the thermostatic control mode for maintaining coldroom temperature.

Compressor Usage Percentage

Information on calculating and storing compressor usage percentage.

Compressor Hours Tracking

Details on storing and displaying compressor operating hours.

Compressor Usage Warnings

Describes warnings related to excessive compressor usage.

Thermostat Probe Failure Actions

Thermostat Probe Failure Actions

Outlines actions taken when the thermostat probe fails.

Timed Adjustment on Failure

Explains timed adjustment criteria during thermostat probe failure.

Weight Adjustment on Failure

Details weight adjustment criteria during probe failure.

Adjustment with Evaporator Probe

Describes adjustment using the evaporator probe during failure.

Defrost Operations

Defrost Modes and Operation

Covers defrost modes, activation, and inhibitions.

Defrost Mode Types

Explains different defrost modes: stop, electric, and hot gas.

Compressor Stop During Defrost

Details compressor stop action during defrost.

Electric Defrost Process

Describes the electric defrost process.

Hot Gas Defrost Process

Explains the hot gas defrost process.

Defrost Activation

Information on initiating defrost cycles.

Defrost Activation Inhibitions

Conditions that inhibit defrost activation.

Defrost Methods and Options

Manual Defrost Activation

Instructions for manual defrost activation.

Timed Defrost Operation

Details timed defrost operations based on ITD hours.

Defrost by Compressor Hours

Describes defrosts based on compressor run hours.

Time-Based Defrosts

Explains time-based defrosts using the real-time clock.

Off & Clean Function

Details the 'Off & Clean' function for melting and drying.

Automatic Defrost Algorithm

Describes the automatic defrosting algorithm.

Ice Detection Sensitivity

Explains setting sensitivity for ice detection.

Protective Defrosts

Information on protective defrosts for specific conditions.

Low Evaporation Reference

Reference to section 7.4 for low evaporation.

Fan Actions During Defrost

Evaporator Fan During Defrost

Details evaporator fan behavior during defrost based on FOP parameter.

Condenser Fan During Defrost

Explains condenser fan behavior during defrost based on FCE parameter.

Defrost Phase Completion

Describes how the defrost phase concludes and subsequent actions.

Double Evaporator Probe Defrost

Defrost management with double evaporator probes.

Defrost Time-Out Management

Information on defrost time-out warnings and settings.

Advanced Defrost Scenarios

Defrost Start During Pull Down

Describes defrost start based on pull-down temperature.

Dual Evaporator Defrost

Details defrost management for dual evaporator systems.

Cascaded Main Defrost

Configuration for cascaded main defrost.

Synchronized Defrost (All)

Synchronizing second defrost with the first.

Synchronized Defrost (After Main)

Synchronizing secondary defrost after main defrosts.

Thermal Protection

Thermal Protection System

Details thermal protection criteria and actions.

Thermal Protection Criteria

Conditions required to enable thermal protection.

Thermal Protection Description

Explains the thermal protection criteria during operation.

Relay U2 Action (Electric Defrost)

Actions of relay U2 during electric defrost.

Relay U2 Action (Cycle Inversion)

Actions of relay U2 during cycle inversion defrost.

Evaporator Fan Operations

Evaporator Fan Operation

Covers evaporator fan operation modes and conditions.

Evaporator Fans & Compressor Sync

Evaporator fan operation linked to compressor status.

S2 Probe Faulty Fan Behavior

Fan behavior when S2 probe is faulty or not installed.

Independent Evaporator Fans

Details independent evaporator fan operation.

S2 Probe Faulty Fan Behavior (Independent)

Fan behavior when S2 probe is faulty or not installed (independent).

Evaporator Fans During Door Opening

Evaporator fan behavior during door opening.

Low Temp Evaporator Fault Handling

Actions taken for low temperature evaporator faults.

Condenser Fan Operations

Condenser Fan Operation

Covers condenser fan operation modes and conditions.

Condenser Fans & Compressor Sync

Condenser fan operation linked to compressor status.

S3 Probe Faulty Fan Behavior

Fan behavior when S3 probe is faulty or not installed.

Independent Condenser Fans

Details independent condenser fan operation.

S3 Probe Faulty Fan Behavior (Independent)

Fan behavior when S3 probe is faulty or not installed (independent).

High Condensation Fault Management

Details actions for high condensation faults.

High Condensation Detection & Stop

Detection and stop actions for high condensation.

High Condensation Fault Reset Time

Information on fault reset time for high condensation.

Condenser Warnings and High Pressure Control

Faults by Event Number

Describes fault handling based on event count.

Alarm Clearing Procedure

Procedure for clearing alarms.

Clogged Condenser Warnings

Details warnings for clogged condenser issues.

Clogged Condenser Detection

Detection criteria for clogged condenser warning.

Clogged Condenser Warning Inhibitions

Conditions that inhibit the clogged condenser warning.

Clear Clogged Condenser Warning

Procedure for clearing clogged condenser warnings.

High Pressure Control Logic

Covers the control logic for high pressure events.

Automatic High Pressure Reset

Details automatic reset procedures for high pressure.

Manual High Pressure Reset

Explains manual reset procedures for high pressure.

Buzzer Silence and Alarm Reset

Procedure for silencing buzzers and resetting alarms.

Accessory Functions

Accessory Function Details

Details various accessory functions of the controller.

Light, Heating, and Resistor Functions

Covers light, heating, frame resistor, and drain resistor functions.

Remote Alarm and Compressor Functions

Details remote alarm relays and the second delayed compressor function.

Defrost Management 2 Reference

Reference to defrost management section.

Specific Accessory Functions

Drying Resistor Function

Details the drying resistor function.

Swivel Plate Function

Information on the swivel plate function.

Active Loads Function

Details the active loads function.

Electric Valve Function

Describes the electric valve function.

Winery Function Details

Details the winery function for temperature monitoring.

Pastry;Ice Cream Function

Explains the pastry/ice cream function.

Second Thermostat (FLEX)

Configuration for a second thermostat function on FLEX panels.

Showcase Mode (FLEX)

Details the showcase mode for FLEX panels.

Recirculation Fan (FLEX)

Information on the recirculation fan for FLEX panels.

FLEX Panel Specific Functions

Light Off Schedule (FLEX)

Sets the schedule for turning off the light on FLEX panels.

Unit Start Time (FLEX)

Sets the unit activation time from Stand-by on FLEX panels.

Humidity Control

Humidity Control Without Probe

Details humidity control using evaporator fan timing without a dedicated probe.

Humidity Control Adjustment

Explains the adjustment criteria for humidity control.

Special Functions and Energy Saving

Off & Clean Function Details

Describes the Off & Clean function for ice cream cabinets.

Off & Clean Purpose

Explains the purpose of the Off & Clean function.

Off & Clean Phases

Details the phases involved in the Off & Clean function.

Energy Saving Features

Covers energy saving features and modes.

Economy Function

Explains the ECONOMY function for reducing consumption.

Economy Feature Activation

Details activation and deactivation of economy features.

Ecomode Function

Describes the ECOMODE function for cabinet consumption reduction.

Temperature Alarms

Temperature Alarm Overview

Details types of temperature alarms and their parameters.

Temperature Alarm Types

Lists the different types of temperature alarms detected.

High Temperature Alarm Details

Explains high temperature alarms and related parameters.

High Temp Pre-Alarm Warnings

Details pre-alarm warnings for high temperatures.

Alarm Notice and Storage

Information on how alarms are noticed and stored.

Temperature Alarm End Conditions

High Temperature Alarm End

Describes the conditions for ending a high temperature alarm.

Low Temperature Alarm Details

Explains low temperature alarms and related parameters.

Low Temp Pre-Alarm Warnings

Details pre-alarm warnings for low temperatures.

Low Temp Alarm Notice;Storage

Information on low temperature alarm notice and storage.

Low Temperature Alarm End

Describes the conditions for ending a low temperature alarm.

Specific Temperature Alarms

High Temp Alarm (Door Opening)

Details high temperature alarms caused by door openings.

Door Opening Pre-Alarm Warnings

Pre-alarm warnings for high temperature due to door opening.

Door Opening Alarm Notice;Storage

Alarm notice and storage for door opening related alarms.

Door Opening Alarm End

Conditions for ending high temperature alarms from door opening.

Black-Out Temperature Alarms

Details alarms related to power outages.

Black-Out Alarm Enable;Disable

Enabling or disabling black-out temperature alarms.

Black-Out Alarm Logic;Storage

Logic and storage for black-out temperature alarms.

FSC Accessory Module

FSC Accessory Module

Details the FSC accessory module for fan speed control.

FSC Module Mode Selection

Selection of operating modes for the FSC module.

FSC Module Manual Mode

Configuration of the FSC module in manual mode.

FSC Automatic Condenser Mode

Details automatic condenser fan control via FSC module.

FSC Automatic Evaporator Mode

Explains automatic evaporator fan control via FSC module.

Superparameters

EVO Parameter Settings

Settings for EVO superparameters related to display and cabinet options.

IS1 Parameter Settings

Settings for IS1 superparameters related to input configurations.

IS2 Parameter Settings

Settings for IS2 superparameters related to probe configurations.

OS1 Parameter Settings

Settings for OS1 superparameters related to output configurations.

OS2 Parameter Settings

Settings for OS2 superparameters related to fan and shutdown options.

FOP Parameter Settings

Settings for FOP superparameters related to fan control.

DOP Parameter Settings

Settings for DOP superparameters related to defrost control.

LGH Parameter Settings

Settings for LGH superparameters related to light and module setup.

Controller Parameters (1-36)

Controller Address Setting

Parameter for setting the controller's network address.

High Alarm Limit Setting

Parameter defining the high temperature alarm limit.

Low Alarm Limit Setting

Parameter defining the low temperature alarm limit.

Alarm Delay Setting

Parameter for setting the delay before an alarm is triggered.

Evaporator Fan Setpoint

Parameter for setting the evaporator fan setpoint.

Condenser Fan Setpoint

Parameter for setting the condenser fan setpoint.

Controller Parameters (37-72)

High Condenser Recovery Time

Parameter for recovery time after high condenser temperature.

Defrost 1 End Temperature

Parameter defining the end temperature for defrost phase 1.

Defrost 1 Time-Out

Parameter for the defrost time-out for phase 1.

Ice Sensitivity Setting

Parameter for setting ice sensitivity in automatic defrost.

Max Compressor Usage for Ecomode

Parameter for max compressor usage to start Ecomode.

User Setpoint

Parameter for the user-defined setpoint temperature.

Controller Parameters (73-92)

U1 Relay Action Setting

Parameter defining the action for U1 relay.

Door Open Alarm Delay

Parameter for alarm delay due to door opening.

OFF&CLEAN Fan Time Before Standby

Parameter for fan time in OFF&CLEAN before standby.

Second Zone Setpoint

Parameter for setting the second zone setpoint.

Defrost Start Temp Decrease

Parameter for temperature decrease at defrost start.

FLEX Panel Architecture

FLEX Controller Architecture Overview

Describes the architecture of the FLEX controller and its connectivity.

Left Side Display Icons

Labels for icons on the left side of the display.

Right Side Display Icons

Labels for icons on the right side of the display.

Lower Display Icons

Labels for lower icons on the display.

FLEX Panel Menu Navigation

Menu Navigation Guide

Explains how to access and navigate through the controller's menu system.

Set Temperature via Menu

Instructions for setting the temperature setpoint via the menu.

Start Defrost via Menu

Procedure for initiating a defrost cycle through the menu.

Set High Temp Limit via Menu

How to set the high temperature limit via the menu.

Set Low Temp Limit via Menu

How to set the low temperature limit via the menu.

FLEX Panel Menu Items

Reading Event List

How to read the event list, including alarms and faults.

Reading Probe Values

How to view probe values from the menu.

Lower Display Configuration

Configuration options for the lower display settings.

Cancelling Event List

Procedure for cancelling the event list.

Parameter and Clock Settings

Parameter Programming Guide

Guide to programming controller parameters, including password entry.

Clock and Date Setting

Instructions for setting the clock and date on the controller.

Service and Network Settings

Service Password Management

Procedure for setting or changing the service password.

LAN and Wi-Fi Configuration

Configuration of network parameters, including Wi-Fi settings.

Compartment Light Schedule

Setting the schedule for turning off the compartment light.

Unit and Humidity Settings

Unit Start Hour Setting

Setting the start-up time for the refrigeration unit.

Setting Humidity Level

How to set the humidity level via the menu.

Setting Second Zone Temperature

How to set the temperature for a second zone.

Local Connectivity - CONNEX Application

CONNEX Application Features

Details the various functions available through the CONNEX application for controller management.

App Temperature and Event Features

App functions for reading temperature, setting setpoints, and viewing events.

App Configuration and Data Features

App functions for configuration, energy saving, alarms, and device data.

Wi-Fi Settings and User Registration

Wi-Fi Settings and User Registration

Steps for setting up Wi-Fi and user registration for the controller.

Remote Connectivity via Web Pages

Remote Connectivity via Web Pages

Connecting to the device remotely via web pages for monitoring and reports.

Atex ECO 6 Specifications

General IconGeneral
BrandAtex
ModelECO 6
CategoryController
LanguageEnglish