ATG429EBPOperationManual
67
June4,2015
Rev.A2
LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS
353 0D0/1 EIS Vibration-L 0-5.12 Scaler
353 0D0/2 EIS Vibration-R 0-5.12 Scaler
353 03D/x AVM Highest Vibration 0-5.12 Scaler
354 03D/x AVM N1 Vibration 0-5.12 Scaler
355 03D/x AVM N2 Vibration 0-5.12 Scaler
356 03D/x AVM N3 Vibration 0-5.12 Scaler
357 03D/x AVM BB Vibration 0-5.12 Scaler
360 03D/x AVM N1 Rotor Imb Ang 0-360 Degrees
361 03D/x AVM LPT Rotor Imb Ang 0-360 Degrees
Note1: x = Any SDI
Note 2: The number entered in the Range Column is the nearest whole binary number greater than the
parameter range required. The weight of the most significant bit of the two's complement fractional
notation binary word will be one half this value, and the actual maximum value of the parameter capable
of being encoded will be the number in the range column less one least significant bit value.