14
IN CASE OF PROBLEM
Problem Check
The device does not heat - Check that the premise circuit breakers are triggered or that the
shedder (if you have one) has not interrupted the device’s power
suply.
- Check the air temperature in the room.
- Switch the heating off, then back on (
switch):
• If the
indicator blinks 3 times: the measurement probe is dama-
ged. Call your electrician to ensure its replacement.
• If the
indicator blinks 5 times: power surge in device supply.
Power off the device (fuse, circuit breaker…), and call your electri-
cian.
The heating device
heats constantly
- Check that the device is not located in a draft or that the tempera-
ture setting has not been altered.
The device’s surface is very
hot
It is normal for the device to be hot when it is operating. The maxi-
mum surface temperature is restricted in accordance with the NF
Electricité Performance standard. However, if you think that your
device is always too hot, check that the output is suitable for the area
of your room (we recommend 50W / m
3
) and that the device is not
placed in a draught, which would disrupt its setting.
The last elements top and
bottom are cooler than the
rest of the device
- At the top, the upper elements are not completely filled to allow
for expansion of the thermodynamic fluid. They heat up only by
conduction.
- At the bottom, the elements convey the fluid return, which has
transmitted its heat.
The device does not follow
the programming instruc-
tions
- Ensure that the programming unit is being used correctly (refer to
its operating manual).
- When ventilating the room, stop the heating by setting the switch
to the Arrêt position.
- If you leave for several hours, lower the temperature.
Leaving for: Less than 24 hours :do not touch the controls.
More than 24 hours or during summer :set the temperature knob to .
RECOMMENDATIONS OF USE
MAINTENANCE
- To maintain the performance of the device, about twice per year, clear the dust.
Do not use abrasive products.