result of both water expansion during heating and also pressure
uctuations.
The supplied PTR valve must be tted with Teon tape. Do not use paste
or hemp.
DN15 copper drain lines must be connected to the discharge pipe of the
PTR valve. The copper drain line must fall away from the ESWH and
be installed in a frost- free environment.
The termination point of a drain line must comply with the requirements
of AS/NZS 3500.4
WARNING: The Pressure Temperature Relief valve and drain line must
not be sealed or blocked.
Electric Connection
All electrical work must be carried out by a registered electrician and in
accordance with AS/NZ 3000.
The Atlantic ESWH must be lled with water before connection to a
power supply.
Switch o the power before removing the cover to avoid any risk of injury
or electric shock.
The installation must be equipped, upstream of the appliance, with
a bipolar cut-out device (fuse, breaker switch) respecting local
regulations (30 mA earth-leakage breaker).
Always connect the earth conductor of the cable to the earth ground
wire or connect the earth conductor to the appropriate terminal
identied by the symbol.