7
Thermal cut-out
All Atlantic ESWH are equipped with a thermal cut-out with manual
resetting which shuts o the power to the water heater if it
becomes overheated.
If the circuit breaker keeps tripping,
a) Switch o the power before taking any further action,
b) Remove the cover,
c) Check the electrical connections,
If the cut-out continues to trip, replace the thermostat. Never by-pass the
safety device or the thermostat. Connect the power supply only via
the terminal.
The thermal cut-out tted to the auxiliary electric heating element must
be replaced by an authorized agent. Failure to respect this clause
invalidates the warranty.
DANGER: The operation of the thermal cut-out indicates a possibly
dangerous situation. Do not reset the thermal cut-out until the
water heater has been serviced by a qualied person.
Blue
VM / VS / HM SHEATED
230 V~
Brown