During scrolling, the numbers of the screens appear consecutively. For most screens, the unit of
measurement and the related pictograph are shown together with the screen number.
Example: display the number of running hours:
The screen shows the screen number <d.1>, the unit used <hrs> and the related symbol for running hours.
Press Enter key (13) to call up the actual running hours.
Overview of the screens
Digital input
screens
Designation Related topic
<d.in> Digital input status
<d.1> Running hours (hrs or x 1000 hrs) See section Calling-up running hours
<d.2> Motor starts (x 1 or x 1000) See section Calling up motor starts
<d.3> Module hours (hrs or x 1000 hrs) See section Calling up module hours
<d.4> Loading hours (hrs or x1000 hrs) See section Calling up loading hours
<d.5> Load relay (x1 or x 1000) See section Calling up Calling up load
relay
<d.6> Service timer reading (hrs or x 1000 hrs) See section Calling up/resetting the service
timer
<d.7> Actual software version
Parameter
screens
Designation Related topic
<P.1> Selection between local, remote or LAN
control
See section Selection between Local,
Remote or LAN control.
<P.2> Setting a node ID for LAN control and the
channels for Mk 4 and Mk 5
See section Calling up/modifying CAN
address control
<P.3> Settings for IP, gateway and Subnet mask See section Calling up/modifying IP,
Gateway and Subnetmask
<P.4> Pressure band settings See section Calling up/modifying pressure
band settings
<P.5> Pressure band selection See section Modifying pressure band
selection
<P.6> Service timer settings See section Calling up/modifying service
timer settings
<P.7> Temperature unit See section Calling up/modifying unit of
temperature
Instruction book
2920 7140 90 33

Table of Contents