6. Fit air outlet valve (AV). See section Introduction for the location of the valve. Close the valve.
Connect the air net to the valve.
On compressors equipped with a dryer bypass, fit the air outlet valve to the dryer bypass pipe.
7. Connect the condensate drain outlet(s) to a drain collector. See section
Condensate system.
The drain pipes to the drain collector must not dip into the water. If there is a risk for freezing, the
pipes must be insulated.
For draining of pure condensate water, install an oil/water separator which is available from Atlas
Copco as an option. See section
OSCi
8. For compressors with a DD or a DD and PD filter: connect the automatic drain of the filters to a
suitable drain collector.
9. On water-cooled compressors, drain valves, shut-off valves and a regulating valve should be fitted
by the customer in the cooling water piping.
10.
î ë
ï ó ò
*
ï ó ð
l )
ò î
(
ï ë í ï î ò
ë î
(
ò
+
The compressor may automatically restart after voltage failure (if activated, consult Atlas Copco).
The compressor is automatically controlled and may be restarted automatically.