(A): Air inlet temperature
(B): Condensation temperature
(C): Working pressure
(D): Relative air humidity
ñ ò ì í ó ï
+
If operating at a pressure of 10 bar(e) in an ambient temperature of 20 °C and at a
relative air humidity of 100%, the minimum temperature to prevent condensate from forming is 68
°C. Regulate the cooling water flow during loaded operation to obtain a temperature between 70 and
approx. 75 °C at the outlet of the compressor element.
ò î
ð
The operator must apply all relevant Safety precautions. Also consult section
Problem solving.
Keep the doors closed during operation; they may be opened for short periods
only to carry out checks.
When the motors are stopped and LED (8) (automatic operation) is alight, the
motors may start automatically.