to navigate through the menu.
2 Pictograph Automatic operation
3 Pictograph General alarm
4
General
alarm LED
Flashes if a shut-down warning condition exists.
5 Pictograph Service
6 Service LED Lights up if service is needed
7
Automatic
operation
LED
Indicates that the regulator is automatically controlling the
compressor.
8
Voltage on
LED
Indicates that the voltage is switched on.
9 Pictograph Voltage on
10 Enter key
Key to select the parameter indicated by the horizontal arrow.
Only the parameters followed by an arrow pointing to the right
be modified.
11 Escape key To go to previous screen or to end the current action
12 Scroll keys Keys to scroll through the menu.
13 Stop button Button to stop the compressor. LED (7) goes out.
14 Start button
Button to start the compressor. LED (7) lights up indicating that
the Elektronikon regulator is operative.