ϰϲ
1904 0504 83
N
?
<
@ >
O A
? >
Starting from the Main screen (see Main screen):
µ
Move the cursor to the action button Menu and press the enter key (2), following screen appears:
Text on figure
(1) Menu
(2) Regulation
µ
Using the scroll keys , move the cursor to the counters icon (see above, section Menu icon)
µ
Press the enter key, following screen appears:
Text on figure
(1) Counters
(2) Running hours
(3) Motor starts
(4) Load relay
(5)
VSD 1-20 % rpm in % (the percentage of the time during which the motor
speed
was between 1 and 20 %) (compressors with frequency converter)
µ
The screen shows a list of all counters with their actual readings.