13 Cooling air grating, dryer
14 When a duct is foreseen on the air inlet, the ambient temperature sensor need to be
repositioned in such a way that the inlet temperature is monitored.
15 Safety valve
ò
ï
The operator must apply all relevant safety precautions, including those
mentioned in this book
ë ë î
ò ó
ï ë í ï î ò
ë
Fix speed compressors can be sold with option rain protection. With this option, this compressor can be
installed outside under a shelter, in frost free conditions. If frost might occur, the appropriate measures
should be taken to avoid damage to the machine and its ancillary equipment. In this case, and also if
operating above 1000 m (3300 ft), consult Atlas Copco.
ë
ó
The compressor can be moved by a lift truck using the slots in the frame. Take care not to damage the
bodywork during lifting or transport. Before lifting, reinstall the transport securing bolts. Make sure that
the forks protrude from the other side of the frame. The compressor can also be lifted after inserting
beams in the slots. Make sure that the beams cannot slide and that they protrude from the frame
equally. The chains must be held parallel to the bodywork by chain spreaders in order not to damage
the compressor. The lifting equipment must be placed in such a way that the compressor is lifted
perpendicularly. Lift gently and avoid twisting.
In case of units equipped with the Lifting Device Option, it is not allowed to lift
the compressor if the canopy parts or lifting supports are not completely
installed. When the compressor is being lifted, it is also forbidden to come under
the load or to perform maintenance activities to it.
ì í ë î
ò
î ï ì ò î
To preserve the protection degree of the electric cubicle and to protect its
components from dust from the environment, it is mandatory to use a proper
cable gland when connecting the supply cable to the compressor.