Instruction book
6996 0227 40 37
Text on figures
Scroll through the items to select the desired item and press the Enter key to see the details as
explained below.
Overview
Text on figures
Example for service level (A):
The figures at the left are the programmed service intervals. For Service interval A, the programmed
number of running hours is 4000 hours (upper row) and the programmed number of real time hours is 8760
hours, which corresponds to one year (second row). This means that the controller will launch a service
warning when either 4000 running hours or 8760 real hours are reached, whichever comes first. Note that
the real time hours counter keeps counting, also when the controller is not powered.
The figures within the bars are the number of hours to go till the next service intervention. In the example
above, the Vacuum pump was just started up, which means it still has 4000 running hours or 8280 hours to
go before the next Service intervention.
Service plans
A number of service operations are grouped (called Level A, Level B, etc...). Each level stands for a
number of service actions to be carried out at the time intervals programmed in the Elektronikon®
controller.
When a service plan interval is reached, a message will appear on the screen.