Instruction book
82 6996 0227 40
Period
Operation
Daily
Check oil level and condition. (see section Operations instructions / During operation)
Check readings on display.
Monthly (1)
Remove the air filter elements and inspect. Replace damaged or heavily contaminated
elements. Check for possible air and oil leakages.
3-monthly (1)
Check coolers, clean if necessary.
Check the filter elements of the electric cabinet. Replace if necessary
Check the silencer of the vacuum control valve, clean if necessary.
(1) Depending on type of application (normal, medium, harsh) this needs to be done more frequently. Consult your
Atlas Copco Customer Center.
Preventive Maintenance schedule programmed in the Elektronikon for normal applications
Type of application
Action
Normal
Medium
Harsh
Check oil level and condition
Daily
Daily
Daily
Check readings on display
Remove the air filter elements and inspect
Replace damaged or heavily contaminated elements
Monthly
Monthly
Weekly
Check for possible air and oil leakages
Check coolers, clean if necessary
3-Monthly
3-Monthly
Monthly
Check the filter elements of the electric cabinet.
Replace if necessary
Check the silencer of the vacuum control valve, clean
if necessary
Change oil *
4000 hrs (1) (4)
2000 hrs (1) (4)
1000 hrs (1) (4)
Change oil filter
Replace the air filter elements
Clean the scavange line and blow out the restriction
nozzle
Replace the oil seperator elements
4000 hrs (1)
4000 hrs (1)
2000 hrs (1)
Check pressure and temperature readings
Check operation of cooling fans of converter and
clean heatsink
Check vacuum control valve solenoid and gasballast
solenoid valve
Clean coolers
Check and clean cooling fan assembly
Regreasing of motor bearings
Replace the filter element of electric cabinet
8000 hrs (2)
6000 hrs (2)
4000 hrs (2)
Replace the thermostatic valve
Test pressure switch
Replace membrane of vacuum control valve (3)
Motor overhaul
24000 hrs
24000 hrs
24000 hrs
Change lipseal assembly
24000 hrs
24000 hrs
24000 hrs