5. Maintenance
5.1 Preventive maintenance schedule
Warning
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
Stop the vacuum pump.
Switch off the voltage.
Effectively isolate the machine from all sources of under- and/or overpressure
and make sure that the pump system is at atmospheric pressure level.
For detailed instructions, see section Problem solving.
The operator must apply all relevant safety precautions. See section Safety
precautions during maintenance or repair
Warranty - Product Liability
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised parts is not
covered by Warranty or Product Liability.
Service kits
For overhauling or carrying out preventive maintenance, service kits are available (see section Service
kits).
Service contracts
Atlas Copco offers several types of service contracts, relieving you of all preventive maintenance work.
Consult your Atlas Copco Customer Centre.
General
When servicing, replace all removed O-rings and washers.
Intervals
The local Atlas Copco Customer Centre may overrule the maintenance schedule, especially the service
intervals, depending on the environmental and working conditions of the vacuum pump.
The longer interval checks must also include the shorter interval checks.
Preventive maintenance schedule
Operation
Duty**
Normal
Medium
Harsh
Check oil level & condition.(See note below)
24 h
24 h
24 h
Clean dirt trap at pump inlet
Monthly
Monthly
Monthly
Clean anti suck back valve at pump inlet.
Yearly
Yearly
Yearly
Change oil*, oil filter (if installed) & exhaust filter
Mineral oil
4000 h
2000 h
1000 h
Synthetic oil
8000 h
4000 h
1000 h
PFPE oil
8000 h
4000 h
4000 h
Clean the pump, the radiator and the motor fan guard
2000 h
1000 h
500 h
Check the vanes. Replace them, if needed
15000 h
10000 h
5000 h
Check belt condition (GVS 470 630A)
Every 2000 h
or 6 months
Every 2000 h
or 6 months
Every 2000 h
or 6 months

Table of Contents

Other manuals for Atlas Copco GVS 16A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GVS 16A and is the answer not in the manual?

Atlas Copco GVS 16A Specifications

General IconGeneral
BrandAtlas Copco
ModelGVS 16A
CategoryWater Pump
LanguageEnglish

Related product manuals