Instruction book
6996 0224 30 61
GVS
16A
GVS
25A
GVS
40A
GVS
60A
GVS
100A
GVS
200A
GVS
300A
GVS
470A
GVS
630A
Maximum inlet
pressure for
water vapour with
big gas ballast (or
2 GB)
mbar
(a)
N/A
N/A
N/A
60
60
50
70
40
60
Maximum inlet
pressure for
water vapour with
big gas ballast (or
2 GB)
torr
(mm
Hg)
N/A
N/A
N/A
45
45
37.5
52.5
30
45
Maximum water
vapour pumping
rate vapour with
standard gas
ballast
kg/h
0.05
0.08
0.76
1
1.6
3.4
1.3
5
17
Note: Lower temperatures are possible with reduced viscosity oil. This temperature range is defined by
Pneurop for performance conformity testing, but 8°C is the critical point from the motor starting view
point.