Instruction book
Installation proposal for tank mounted compressors with silencing hood
References of figures on installation drawings.
Reference Description
1 Cooling air outlet
2 Compressor air and cooling air inlet
LE
Install the compressor horizontally, in a cool but frost-free and well-ventilated room. Place the compressor as
level as possible; however, LE can be operated with a maximum inclination of 40% (22.5 degrees) in any
direction. The air should be clean.
A Base mounted unit with hood option must be installed away from walls to allow easy maintenance. Keep the
ventilation openings free.
It is recommended to install an automatic condensate drain (available as an option) on the air receiver to ensure
continuous condensate removal.
LE trolley