Service EN LSV39 SA12-125
16
© Atlas Copco Industrial Technique AB - 9839 0621 01
Lubrication Instructions
Rust protection and cleaning
Water in the compressed air can cause rust. To prevent rust we strongly recommend to install an air dryer.
Water and particles can cause sticking of vanes and valves. This can be prevented by installing an air fil-
ter close to the product to avoid pressure drop.
Before longer standstills always protect your tool by adding a few drops of oil into the air inlet. Run the tool
for 5–10 seconds and absorb any access oil at the air outlet in a cloth.
NOTICE Do not try to clear the air path using sharp tools.
The air inlet is equipped with a strainer. If this is punctured, foreign objects may harm the valves, resulting
in overspeed.
Lubrication guide
Grease for general purpose
BP Energrease LS-EP2
Castrol OBEEn UF 1
Esso Beacon EP2
Q8 Rembrandt EP2
Mobil Mobilegrease XHP 222 NLG2
Klüber Lub. Klübersynth UH 1 14-151
Texaco Multifak EP2
Molykote BR2 Plus
Grease for angle gears
Rhenus LKR03