8 Technical data
8.1 Reference conditions
Inlet pressure (absolute) bar 1
Relative air humidity % 0
Air inlet temperature ºC 20
Working pressure:
for LT 15 bar bar(e) 12
for LT 20 bar bar(e) 20
8.2 Limitations
Minimum inlet temperature °C 0
Maximum inlet temperature ºC 40
Maximum working pressure bar(e) See below
Only applicable for Full Feature variants. (with refrigerant dryer)
Minimum ambient air temperature °C 5
8.3 Compressor data
50 Hz (15 bar)
Compressor
type
LT 2 LT 3 LT 5 LT 7 LT 10
Maximum
working
pressure
bar(e) 15 15 15 15 15
Maximum
working
pressure for
Trolley
bar(e) 13.7 13.7 13.7 13.7 13.7
Pre-set
pressure
difference for
Trolley
bar 1 1 1 1 1
Temperature at outlet valve, approx.
- Unsilenced
compressor
ºC 49 57 68 56 75
- Silenced
compressor
ºC 57 65 76 64 83
Instruction book