- 54 -
Clean flow restrictor in oil scavenge line X X
Grease hinges X
Adjust engine inlet and outlet valves (2) X X
Check/Test glow plugs - grid heater X
Test safety valve (9) X
Check rubber flexibles (11) X
Check emergency stop X
Clean after cooler (option) (1) X X
Replace DD/PD/QD filter (option) X X
Change compressor oil (1)(7) X X
Replace oil separator element X X
Clean oil cooler(s) (1) X X
Clean radiator (1) X X
Analyse coolant (4)(8) X
Replace air filter element (1) X X
Check/Replace safety cartridge X X
Inspection by Atlas Copco service technician X X
Check engine & compressor anti-vibration pads X X
Check valve in the fuel return line (for
mechanical injection system)
X X
Maintenance schedule (running hrs) Notes Daily 50 hrs after
initial start-up
Every 250
hrs
Every 500
hrs
Every
1000 hrs
Yearly 2 Yearly