EasyManua.ls Logo

Atmos C15E - 7 Boiler Bases

Atmos C15E
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction manual - GB
www.atmos.cz
GB-13
GB
The boilers maximum output with wet fuel
illustrated in the graph
kW
DC15 E - 8
DC 18 S - 13
DC 22 S - 14
DC 25 S - 19
DC 32 S - 24
DC 40 S(E) - 31
DC 50 S(E) - 39
DC 75 S(E) - 53
The information is relevant to other gasifica-
tion boiler types.
Boilers are not suitable for burning wood with moisture content lower than 12%.
Fuel heating capacity
Wood - type Heating capacity per 1 kg
kcal kJoule kWh
spruce
3900 16250 4,5
pine
3800 15800 4,4
birch
3750 15500 4,3
oak
3600 15100 4,2
beech
3450 14400 4,0
Raw wood does not burn easily, produces a lot of smoke and substantially decreases
the service life of your boiler and chimney. Boiler output drops as low as 50% and fuel
consumption doubles.
7. Boiler bases
Boiler type (mm) A B
DC15E/DC18S/DC22SX
600 600
DC20GS
700 600
DC22S/DC25S/DC30SX
600 800
DC30SE/DC32S/DC25GS/
DC32GS/DC40GS/DC40SX
700 800
DC40SE
700 1000
DC50SE
800 1000
DC50S, DC70S
700 1000
DC75SE
800 1300
We recommend providing a concrete (metal)
base under the boiler.

Table of Contents