8.3 PERIOD OF INACTIVITY OF CABINET
During periods of inactivity, remove the products from the cabinet and
then follow these directions:
- Remove the plug out from the outlet and
carefully clean the unit as per periodic cleaning
- Cover the cabinet whit a cloth that allows air
circulation in the interior. circulation in the interior.
9 TROUBLE SHOOTING AND REMEDIES
Often, the malfunction of a unit is due to simple causes which can easily
be eliminated without contacting a technician.
Therefore execute the following controls
9.1 If the cabinet does not operate,
make sure that:
- - The plug has been correctly inserted into the socket.
- The supply cord is not damaged.
9.2 If the required temperature is not achieved, make sure that;
- The command switch is turned on.
- The electronic control panel is correctly regulated ( see 6.1.3, 6.1.4 ).
- The cabinet is neither in the defrosting phase nor in the
post-defrosting pase.
- - The evaporator is not covered with frost ( see 6.3 ).
- The condenser is not blocked with dust.
- The cabinet is not located near heat sources or its condensing unit
has uninterrupted air flow.