9.
How
to
change
a
parameter
value
To
change
the
parameter's
value
operate
as
follows:
Enter
the
Programming
mode
by
pressing
the
seT
+
"'-:::7
keys
for
3s
("°C"
or
"°F'
LED
starts
blinking).
Select
the
required
parameter.
Press
the
"SET"
key
to
display
its
value
Use
A
or
~AUX
to
change
its
value.
Press
"SET"
to
store
the
new
value
and
move
to
the
following
parameter.
To
exit:
Press
SET+
A
or
wait
15s
without
pressing
a
key.
NOTE:
the
set
value
is
stored
even
when
the
procedure
is
exited
by
waiting
the
time-out
to
expire.
10.
To
lock
the
keyboard.
Keep
pressed
for
more
than
3s
the
"'-:::7
+ A
keys.
The
"OF"
message
will
be
displayed
and
the
keyboard
will
be
locked.
If
a
key
is
pressed
more
than
3s
the
"OF"
message
will
be
displayed.
11.
To
unlock
the
keyboard.
Keep
pressed
together
for
more
than
3s
the
"":::i'
+A
keys
till
the
"on"
message
will
be
displayed
.
12.
Alarm
signalling
.
Me
ss.
Cause
Outputs
"P1"
Room
probe
failure
Compressor
outpu
t
according
to
"Cy"
e
"Cn"
"P2"
Evaporator
probe
fai
l
ure
Defrost
end
is
timed
"HA"
Maximum
temperature
alarm
Outp
u
ts
unchanged
"LA"
Minimum
temperature
alarm
Outputs
unchanged
"EA"
External
al
arm
Outputs
unchanged
"CA"
Serious
external
alarm
All
ou
t
pu
ts
OFF
"dA"
Door
Open
Compressor
and
fans
restarts
m