Alarm Err-E001: The
controller is not connected!
Check whether the RS485
communication line between the touch
screen and the controller is properly
connected, and check whether the
controller is normally powered on and
started.
Alarm Err-B001: The air
pressure is too low!
Check whether the air pressure is
normal.
Alarm Err-L001: Laser
failure!
Check whether the laser is working
properly.
Alarm Err-W001: Wireless
communication failure!
Check whether the green indicator
light of the controller flashes normally, if
the green indicator light is always on, plug
and unplug the wireless receiver again.
This alarm is
only for the
optional wireless
control module.
Alarm Err-S001: Wire
feeder communication failure!
Check the communication line
between the controller and the stepping
wire feeder, and plug the communication
interface again after power off.
This alarm is
only for the
optional stepping
wire feeder.
AlertErr-S002: Stepping
wire feeder driver alarm
Check the line connection between
the motor and the drive, check whether the
power supply voltage is at 24V.
This alarm is
only for the
optional stepping
wire feeder.
Alarm Err-S003: Motor
shaft lock failure!
After the power is off, check the line
connection between the motor interface of
the stepping wire feeder and the motor
driver, and re-plug and unplug the motor
terminal of the driver.
This alarm is
only for the
optional stepping
wire feeder.
Alarm Err-C001: Chiller
alarm!
Check whether the chiller works
normally
Alarm Err-All: There are
many faults at present, please
There are many current faults, please
troubleshoot them one by one.