14) Off light wire feeding
When the light off wire feeding delay is completed, the length of the wire feeded by
wire feeder is determined by this parameter to facilitate wire breakage.
15) Off light wire feeding speed
After the light emission ends, the running speed of the back feed and off light wire
feed.
16) Automatic wire breakage
With this option on, there is a wire breakage action at the end of each wire feeding
and light output. With this option off, there is no wire breakage action at the end of each
wire feeding and light output.
3. Equipment alarm and treatment
3.1 Device alarm
If the alarm is not cleared, the red indicatorr light will flash. The red indicator light will
only disappear after all alarms are cleared (currently no alarms), as shown in the following
figure:
Alarm is not cleared Alarm cleared
3.2 Solutions to the warning
Once the equipment is alarmed, the user must stop using the handheld laser welding
equipment immediately, troubleshoot the fault. Use it only after the fault is resolved. Users
can refer to the alarm information in the alarm window to troubleshoot faults. The alarm
information and solutions are shown in the following table: