Step 12:
The last step before powering the M2/R2 is to remove the fuse
holder on the bottom left side at the back of the device, replace
both of the fuses (the active one and the spare one) by the
T4AL/250V fuse and place the fuse holder back into the device.
Finally, attach POW2 option sticker
at the back of the device.
Ready:
The power amplifier kit is now fully installed and ready to be used. There is no need
for any software adjustments to the matrix system.
Verify if all connections are done correctly and power on the Matrix system.
Test all the loudspeaker outputs separately with a loudspeaker to check if every
channel is working correctly.
Keep the matrix system running for about 1 hour, and check if the cooling fan is
working correctly. The cooling fan is temperature controlled which means that it won’t
rotate once the system is powered ON, but will start working once the temperature
inside the device is increasing.
POW2 option inside
1 4 0 8 0 3 0 6 5 7 0 0 0 1
S/N:14080306570001
Fuse Installed:
T4AL/250V