Manual Calibration
If you prefer not to use Sonarworks, then third-party measurement software can be
used instead. The included Sonarworks Reference Microphone can be used for this,
or you can use your reference mic if preferred.
If using a third party software, it is not possible to directly import your settings into
ORIA, the speaker calibration settings must be entered manually.
The third party software should give you an EQ curve you can apply to each channel,
as well as Trim and Delay settings. These settings can then be entered manually for
each channel as explained in the Setup Menu section earlier in this manual.
When manually calibrating, you can adjust the following for each speaker channel:
• EQ (8 bands, 12db, 20Hz - 20kHz + Hi-shelf and Lo-shelf)
• Output Trim ( 6db)
• Delay Time (0-75ms)
• Crossover Point (30Hz - 500Hz)
This allows you to balance your speaker configuration and get the best surround
sweet-spot possible.