Hardware Installation Manual 28 Document #: LTRT-41511
5 Cabling the Device
This section describes how to cable the device:
Grounding the device – see Section 5.1 on page 28
Connecting to the LAN – see Section 5.2 on page 29
Connecting to a computer for serial communication – see Section 5.3 on page 32
Connecting to power – see Section 5.4 on page 33
5.1 Grounding the Device
The procedure below describes how to ground the device.
Protective Earthing
The equipment is classified as Class I according to EN-60950-1 and UL 60950-
1 and must be earthed at all times (using an equipment-earthing conductor).
Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun
pistorasiaan."
Norway: "Apparatet rna tilkoples jordet stikkontakt."
Sweden: "Apparaten skall anslutas till jordat uttag."
To ground the device:
1. Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis' earthing
screw (located on the rear panel), using the supplied washer.
Figure 5-1: Grounding the Device
2. Connect the other end of the strap to a protective earthing. This should be in accordance
with the regulations enforced in the country in which the device is installed.