020530E MAN-050-200, MAIN INSTALLATION MANUAL Page
AUTOMOTIVE AURAGEN
®
MAIN INSTALLATION MANUAL
MOUNTING KIT CONTENTS
• AuraGen Mounting Bracket
• Supplemental brackets
• AuraGen Pulley Assembly
• Necessary serpentine or V belt(s)
• Throttle control & mounting hardware
• Misc. hoses, idlers, tensioners and fasten-
ers to install brackets.
RECOMMENDED AND REQUIRED
TOOLS AND MATERIALS FOR
AURAGEN SYSTEM INSTALLATION
AND TEST
Recommended:
√ S.A.E. wrenches – 7/16" through 1-1/4 "
√ Metric wrenches – 8 mm through 19 mm
√ 1/4", 3/8" and 1/2" ratchets with exten-
sions
√ S.A.E. sockets – 7/16" through 3/4"
√ Metric sockets – 8 mm through 19 mm
√ Hose clamp removal tool or pliers
√ Power steering pump pulley puller
√ Serpentine and/or V belt tensioner tool
√ Phillips head screwdrivers
√ Wire cutters (large and small)
√ Knife
√ Hacksaw
√ Straight edge (24")
√ Torque wrench (10-100 ft-lbs.)
√ Crimping tool
√ Rivnut tool
√ S.A.E. and metric Allen wrench set
√ Tape measure
√ Volt-ohm meter
√ Drill, drill bit, and hole saw set
√ Scribe
√ Fender covers
√ Misc. Items:
Marker , drain pan for engine coolant,
drop light
MOUNTING KIT
The mounting kit allows proper installation and
mounting of the AuraGen to the vehicle engine.
When installed properly, the serpentine belt will
line up with all idlers and tensioners. The
mounting kit is always vehicle and engine
specific. You must have the correct mounting
kit for the particular make, model year and
engine configuration of the vehicle into which
the AuraGen system is to be installed. Each
mounting kit contains a mounting bracket to
which the AuraGen is attached and related
mounting hardware.
Due to possible OEM midyear design varia-
tions, attempts to install an AuraGen kit on chas-
sis models and engine configurations not de-
fined in the AuraGen Induction Power Source
Catalog, or the presence of aftermarket equip-
ment, incompatibilities may be experienced
with the AuraGen mounting kit and/or informa-
tion provided in this manual. Although Aura will
assist the installer to resolve these types of con-
ditions, it cannot be held responsible for addi-
tional installer labor, time, and costs associated
with such variations.
ESTIMATED INSTALLATION TIME
An experienced two person crew will need
between two and four hours for a standard
installation that includes a remote power strip.
AURAGEN SYSTEM
COMPONENTS
• AuraGen Power Induction Source
• AuraGen Control Panel
• AuraGen Electronic Control Unit/Inverter
Charger System (ECU/ICS)
• Mounting hardware for the ECU/ICS
• AuraGen Signal Harness
• Power cable (Not Included with mounting kit.
See Required Additional Material).
1-6