EasyManua.ls Logo

AuraMist AM11MF30-1 - User Manual

Default Icon
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
30” Misting/Oscillating Fan
Model Number AM11MF30-1
Rev. A 05/31 AM11MF30-1 1
READ AND SAVE THESE INSTRUCTIONS
CAUTION:
Before using this product read this manual and follow all safety rules and
operating instructions. Failure to comply with instructions will void the warranty
and could result in personal injury and/or property damage.
IMPORTANT:
For replacement parts or assembly questions call 1-800-320-6478 or go to
www.auramist.net
TABLE OF CONTENTS
1. Safety Information…………………… 1
2. Hardware Package Contents………. 2
3. Carton Contents……………………... 3
4. Assembly……………………………... 3
5. Operation…………………………….. 6
6. Maintenance…………………………. 7
7. Storage……………………………….. 8
8. Troubleshooting……………………… 8
9. Warranty…………………………….... 8
SAFETY INFORMATION
1. Read all instructions before using the Misting Fan.
This product is designed to operate with
DRINKING WATER ONLY. City water supply,
bottled water, and other sources deemed suitable
for human consumption will ensure optimal
functionality of the system throughout
maintenance intervals. In the event that another
liquid other than DRINKING WATER is used to fill
the water tank, immediately drain the contents of
the tank and contact customer service regarding
steps to take to help determine the usability of
your system.
2. Make sure that the power source complies with
the electrical requirements of the Misting Fan.
3. Use this Misting Fan only as described in this
manual. Any other use may cause electrical
shock, fire, injury to persons or animals and may
void the warranty.
4. To reduce the risk, of personal injury, the misting
fan should not be used as a toy or placed where
small children can reach it.
WARNING: DO NOT USE THE FAN MOTOR
OR THE MISTING ON-OFF SWITCHES AS THE
MEANS OF DISCONNECTING POWER WHEN
INSTALLING OR SERVICING THIS PRODUCT.
ALWAYS DISCONNECT THE POWER CORD.
5. Disconnect the power cord before moving or
performing any maintenance on the Misting Fan.
6. This Misting Fan shall not be used in potentially
dangerous conditions, such as flammable,
explosive or chemically loaded environments.
7. The Misting Fan shall be completely assembled,
according to these instructions before connecting
to a power source.
WARNING: DO NOT USE A THREE PRONG TO
TWO PRONG ADAPTER. IMPROPER
CONNECTION MAY CREATE A RISK FOR
ELECTRICAL SHOCK.
8. The power cord of the Misting Fan is equipped
with a three prong grounded plug, and it shall be
connected into the corresponding power
receptacle. Under no circumstance, shall the
grounding leg be removed or bypassed from the
power cord plug.
9. If the use of an extension cord is required,
minimize the risk of overheating or fire by ensuring
the extension cord is UL, ETL, CETL or CSA
listed. Do not operate more than one Misting Fan
per extension cord.
10. Do not operate the Misting Fan with a damaged
power cord, plug or after the Misting Fan is
damage in any manner. Call an authorized
service center for evaluation, adjustment or repair.
11. Do not insert or allow any foreign objects to enter
the intake or exhaust air openings, as it may
cause mechanical, electrical, or fire damage to the
Misting Fan.
12. Do not block or tamper with the Misting Fan
nozzles, as it may reduce or impede the
functionality or quality of the Misting Fan. Call an
authorized service center for evaluation,
adjustment or repair.
13. Always place the Misting Fan on a stable flat
surface to avoid the chance of tipping over the
Misting Fan.
14. Never placed the Misting Fan where it may fall into
a water reservoir (example: bathtub, pool), or
anything containing an electrical conductive
substance.
15. When the product is used outdoors, use only on
GFCI (Ground Fault Circuit Interrupter) protected
receptacles.
CAUTION: THIS MISTING FAN SHALL BE
ASSEMBLED ACCORDING TO THESE
INSTRUCTIONS, DUE TO ITS WEIGHT AND
SIZE. FAILURE TO DO SO COULD RESULT IN
THE PRODUCT COMING APART DURING
OPERATION AND/OR PERSONAL INJURY.

Questions and Answers

  • A
    Amanda ScottAug 2, 2025
    What to do if my AuraMist Fan is not misting?
    • J
      joshuaolsonAug 2, 2025
      If the AuraMist Fan is not misting, it could be due to several reasons. First, ensure the water tank is filled with drinking water. If the tank is full, the system may need priming as described on operation page 6. Check that the misting valve is open by turning it counterclockwise. If the problem persists, the water filter might need replacement, or the system may have run dry, refer to the automatic shutoff procedure on page 6.
  • S
    sarah69Aug 8, 2025
    What to do if my AuraMist AM11MF30-1 is not running?
    • A
      Andrew BarrettAug 8, 2025
      If your AuraMist Fan is not running, check that the power cord is properly connected. Also, make sure the switch is not in the “OFF” position; pull the fan switch to turn it on.
  • K
    kristaramirezAug 14, 2025
    How to fix the AuraMist Fan power base if it's not running?
    • T
      trevinorogerAug 14, 2025
      If the power base of your AuraMist Fan is not running, first ensure the power cord is properly connected. Second, check that the switch is rotated to the “ON” position.
  • K
    Kent HowardAug 20, 2025
    Why is water streaming from the nozzle of my AuraMist AM11MF30-1 Fan?
    • P
      Patricia HarrisAug 21, 2025
      If water is streaming from the nozzle of your AuraMist Fan, it may be because the air filter needs replacing. Another potential cause is leaky air hoses; to check, turn off the fan motor and feel for any air leaks on the hoses. Lastly, there might be a foreign object in the nozzle, in which case you should order and replace the nozzle holder.
  • R
    Richard ButlerAug 27, 2025
    Why is water dripping from the drain plug of my AuraMist AM11MF30-1 Fan?
    • T
      Tracy ManningAug 27, 2025
      If water is dripping from the drain plug of your AuraMist Fan, ensure the drain plug is properly seated. Also, check if the drain plug seal is missing or damaged, and replace it if necessary.

Summary

Safety Information

Hardware Package Contents

Carton Contents

Fan Pole Assembly to Power Base Assembly

Fan Pole Assembly to Motor Assembly

Fan Guard and Blade Assembly

Air, Water and Electrical Connections

Operating Instructions

Fan Operation (Speed and Oscillation)

Controls fan speed, ON/OFF, and oscillation angle for operation.

Misting Operation

Details on filling the tank, priming the system, and adjusting mist density.

Maintenance

Adjusting Mist Density

Optimize cooling by adjusting mist output using the control valve.

Emptying Water Tank

Procedure for safely draining the water tank.

Cleaning Basket Filter

Instructions for cleaning the filter inside the water tank.

Conditioning Water Tank

Recommended procedure for maintaining the water tank.

Replacing Filters

Guide for replacing air and water filters for optimal performance.

Storage

Troubleshooting

Warranty

AuraMist AM11MF30-1 Specifications

General IconGeneral
ModelAM11MF30-1
CategoryFan
TypeMisting Fan
Power SourceElectric
Voltage120V
Power Consumption75W
Fan Speed Settings3
Coverage Area300 sq ft
MaterialPlastic
ColorWhite

Related product manuals