C300H / C300HI / C300H x4 / C300HI x4
C350H / C350HI / C350H x4 / C350HI x4
103
Coolant circuit: Filling and bleeding
- Before filling the circuit, re-connect the lower radiator hose.
Modelos C300H / C300HI (fig. 1)
- The circuit is filled through the filling cap (a) located under the top cover of the
counterweight.
Modelos C300H x4 / C300HI x4 / C350H / C350HI / C350H x4 / C350HI x4 (fig. 2)
- The circuit is filled through the filling cap(b) of the coolant reservoir.
Proportions of coolant and distilled water:
Temperatures from 1.4º F to 260.6 ºF (-17 ºC to 127 ºC): 40 % glycol and 60 % distilled
water.
Temperatures from -35º F to 293 ºF (-35 ºC to 145 ºC): 50 % glycol and 50 % distilled
water.
- Start the engine until the thermostat opens.
- Then, when the engine is cold, check the level of coolant in the coolant reservoir.
- If necessary, bleed the coolant air circuit using the bleeder located on the radiator
hose (fig. 3).
NOTE
Although the cooling system is equipped with a self-bleeding system, refer to
an authorized AUSA dealer for the replenishment of the coolant after draining
it.
Dispose of used coolant in authorized centres.
(fig. 3) (fig. 2) Kubota V3600 (fig. 1) Kubota 2403-M
Periodic
Maintenance
Operations
a