Doc. No. E1.01.01-E Rev. 6 10-March-2011 Page 6-2
6.2.1 Power Curve
6.3 Operating Limitations
6.3.1 Engine RPM
Maximum for take–off (for 3 mins) 7 500 RPM
Maximum Continuous 6 900 RPM
Maximum Overspeed (20 sec. limit) 7 800 RPM
Idle Minimum 1 750 RPM
6.3.2 Ambient Temperature Limits
Minimum Starting Ambient (without priming) -10 °C
Maximum Ambient +55 °C