AE50R, AE50RA
AE50RAB
Engine Manual
Doc. No. E1.01.0-E Rev. 6 10-March-2011 Page 15-2
15.4 Ground Run Check List (example)
ENGINE GROUND RUND RESULTS
Date:……………….. A/C Reg……………….. Engine No………………..
Flight Hours……………….. Total Running Time (hrs meter)………………..
QFE……………….. Outside Air Temperature………………..
Instrumentation – Gauge / Alarm Function Test
Pressure Temperature Others
RCAO Battery Fail Alarm
Low Fuel Pressure Alarm Engine Coolant Charge System Fail Alarm
OAT Flytronic Error Warning
EGT 1 (optional) Fuel Flow
Oil Low Alarm
Record data after 1 minute steady running at each condition after warm – up
Engine Coolant RCAO Remarks
RPM Temp Temp
Warm – up ………. ………… ………. ……………
Idle ………. ………… ………. ……………
5000 ……….. ………… ………. ……………
6000 ……….. ………… ………. ……………
Max ………. ………… ………. ……………
Idle ………. ………… ……….. ……………
Ign. 1 Ign. 2
Mag Drops at 6000 RPM ………. ……….
Acceleration tests (3 off) Remarks
(Idle to Max RPM response) ………………………………………………….
(1 sec throttle time) ………………………………………………….
Comments If any adjustments are made as a result of this ground run they
should be recorded and the ground run repeated
…………………………………………………………………………………………………………….
…………………………………………………………………………………………………………….
…………………………………………………………………………………………………………….
Record results in engine maintenance file !