Jam Errors
S
Code
Error Action Message
S1 Platter never
moved or
sensors not
connected.
1. Take no action
2. Throw error
3. Lock the screen.
“Motor/Sensor
unresponsive on platter X
See Supervisor”
Move Cycle
Speed
Accel. Decel.
Ramp Ramp
Notes: This error occurs normally when a motor is not functioning or disconnected or it’s sensors /
encoders are not functioning and will occur at the beginning of the fetch cycle (see diagram above) . The
administrator should check the connections first. Everything appears normal; the next step would be to
begin changing the components with a functioning platter to identify the problem part.
Time
S1
Full speed part
Of move
Check 2
Check 1
Fetch Begins Fetch Ends