EasyManua.ls Logo

AutoCrib C - Jam Error Codes S2 and S3

AutoCrib C
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AUTO
CRIB
S
Code
Error Action Message
S2 Platter started
to move then
stopped/.
1. Take no action
2. Throw error
3. Lock the screen.
“Motor/Sensor
unresponsive on platter X
See Supervisor”
Move Cycle
Speed
Accel. Decel.
Ramp Ramp
Notes: An S2 error is typically caused by one of 2 conditions.
1. The system begins to turn the platter but encounters a hard Jam (something stuck in the chain etc.)
In this case the administrator should remove the side panel of the machine and inspect the affect
platter and chain for any possible obstructions. If there are none the next step should be to attempt
to move the platter with the manual switches. If the machine will moves then proceed to the step 2
2. The other possible condition is the sensors/encoder is not reporting the movement or pulses back
to the controller. This will cause the machine to stop immediately after it starts. The
administrator should check all connections and proper functioning of the sensors.
Time
S2
Full speed part
Of move
Check 2
Check 1
Fetch Begins Fetch Ends
28