Digital Counter / Timer / Tach User Manual, 1st Ed.
1-800-633-0405
2-116
Mode C (
C
)
When the count present value PV counts up to the count setting
value SV both outputs 1 and 2 will turn ON momentarily for
the time set in the output pulse width parameter (
tout2
) and
the count PV will reset automatically to 0.
The leading edge of a “reset” input signal at RST1 will turn
OFF both outputs, reset the count present value PV to 0, and
prohibit an input signal from incrementing the count PV. The
trailing edge of the “reset” signal at RST1 enables counting to
begin.
The “reset” signal minimum pulse width is set by reset pulse
width parameter (
rtSr
) or DIP Switch 8.
999999
SV
PV
OUT2
OUT1
TTT
DUAL
Input Mode ADDITION
TTT
0
Mode R (
r
)
When the count present value PV counts up to the count setting
value SV both outputs 1 and 2 will turn ON momentarily for
the time set in the output pulse width parameter (
tout2
). The
count PV is prohibited from incrementing until the end of the
output pulse time (
tout2
) when the outputs turn OFF and the
count PV is reset automatically to 0.
The leading edge of a “reset” input signal at RST1 will turn
OFF both outputs, reset the count PV to 0 and prohibit an
input signal from incrementing the count PV. The trailing edge
of the “reset” signal at RST1 enables counting to begin.
The “reset” signal minimum pulse width is set by reset pulse
width parameter (
rtSr
) or DIP Switch 8.
999999
SV
PV
OUT2
OUT1
T
T
DUAL
Input Mode ADDITION
TT
0
Mode K (
k
)
When the count present value PV counts up to the count setting
value SV both outputs 1 and 2 will turn ON momentarily for
the time set in the output pulse width parameter (
tout2
). The
count PV will continue to increment with each input signal.
The leading edge of a “reset” input signal at RST1 will turn
OFF both outputs, reset the count PV to 0 and prohibit an
input signal from incrementing the count PV. The trailing edge
of the “reset” signal at RST1 enables counting to begin.
The “reset” signal minimum pulse width is set by reset pulse
width parameter (
rtSr
) or DIP Switch 8.
RESET
999999
SV
PV
OUT2
OUT1
T
T
DUAL
Input Mode ADDITION