DL06 Micro PLC User Manual, 3rd Edition, Rev. E
5-77
Chapter 5: Standard RLL Instructions
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
B
C
D
NOTE: Status flags are valid only until another instruction uses the same flag.
In the following example, when X1 is on, the value in V2000 will be loaded into the accumulator
using the LD instruction. The value in the accumulator is exclusive ORed with V2006 using
the XOR instruction. The value in the lower 16 bits of the accumulator is output to V2010
using the OUT instruction.
XOR
A aaa
XOR (V2006)
Handheld Programmer Keystrokes
LD
V2000
X1
Load the value in V2000 into
the lower 16 bits of the
accumulator
XOR
V2006
XOR the value in the
accumulator with
the value in V2006
OUT
V2010
Copy the lower 16 bits of the
accumulator to V2010
0010 100001111010
01000010010000100000010000000000
V2000
287A
00000000000000 00
0000000000000000
The upper 16 bits of the accumulator
will be set to 0
15 14 13 12 11 10 9876543210
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 1631 30 29 28 27 26 25 24 23 22 21 20 19 18 17
16
Acc.
Acc.
00101000011110100000000000000000
Acc.
6A38
V2010
4242
Direct SOFT32
01101010001110000000000000000000
STR
$
SHFT
SET
X
1
B
ENT
SHFT
ANDST
L
3
D
SHFT
AND
V
2
C
0
A
0
A
0
A
ENT
SHFT
AND
V
2
C
0
A
0
A
ENT
6
G
OUT
GX
SHFT
AND
V
2
C
0
A
1
B
0
A
ENT
OR
Q
SHFT
SHFT
SET
X
Operand Data Type DL06 Range
A
aaa
V-memory V See memory map
Pointer P See memory map
Discrete Bit Flags Description
SP63 ON if the result in the accumulator is zero.
SP70 ON if the result in the accumulator is negative.
DS Used
HPP Used
DirectSOFT
Exclusive Or (XOR)
The XOR instruction is a 16-bit instruction that performs
an exclusive OR of the value in the lower 16 bits of the
accumulator and a specified V-memory location (Aaaa).
The result resides in the in the accumulator. The discrete
status flag indicates if the result of the XOR is zero.